Cardiac allograft vasculopathy (CAV) is the leading cause of morbidity and mortality in heart transplantation (HT). We sought to investigate the role of coronary flow reserve (CFR) by contrast-enhanced transthoracic echocardiography (CE-TTE) in CAV diagnosis. CAV was defined as maximal intimal thickness (MIT) assessed by intravascular ultrasound (IVUS) >= 0.5 mm. CFR was assessed in the left anterior descending coronary artery in 22 HT recipients at 6 +/- 4 years post-HT. CAV was diagnosed in 10 patients (group A), 12 had normal coronaries (group B). The mean MIT was 0.7 +/- 0.1 mm (range 0.03-1.8). MIT was higher in group A (1.16 +/- 0.3 mm vs. 0.34 +/- 0.07 mm, p < 0.0001). CFR was 3.1 +/- 0.8 in all patients and lower in group A (2.5 +/- 0.6 vs. 3.7 +/- 0.3, p < 0.0001). CFR was inversely related with MIT (r = -0.774, p < 0.0001). A cut point of < 2.9, identified as optimal by receiver operating characteristics analysis was 100% specific and 80% sensitive (PPV = 100%, NPV = 89%, Accuracy = 91%). CFR assessment by CE-TTE is a novel noninvasive diagnostic tool in the detection of CAV defined as MIT >= 0.5 mm. CFR by CE-TTE may reduce the need for routine IVUS in HT.

Coronary flow reserve by transthoracic echocardiography predicts epicardial intimal thickening in cardiac allograft vasculopathy

MONTISCI, ROBERTA;
2010-01-01

Abstract

Cardiac allograft vasculopathy (CAV) is the leading cause of morbidity and mortality in heart transplantation (HT). We sought to investigate the role of coronary flow reserve (CFR) by contrast-enhanced transthoracic echocardiography (CE-TTE) in CAV diagnosis. CAV was defined as maximal intimal thickness (MIT) assessed by intravascular ultrasound (IVUS) >= 0.5 mm. CFR was assessed in the left anterior descending coronary artery in 22 HT recipients at 6 +/- 4 years post-HT. CAV was diagnosed in 10 patients (group A), 12 had normal coronaries (group B). The mean MIT was 0.7 +/- 0.1 mm (range 0.03-1.8). MIT was higher in group A (1.16 +/- 0.3 mm vs. 0.34 +/- 0.07 mm, p < 0.0001). CFR was 3.1 +/- 0.8 in all patients and lower in group A (2.5 +/- 0.6 vs. 3.7 +/- 0.3, p < 0.0001). CFR was inversely related with MIT (r = -0.774, p < 0.0001). A cut point of < 2.9, identified as optimal by receiver operating characteristics analysis was 100% specific and 80% sensitive (PPV = 100%, NPV = 89%, Accuracy = 91%). CFR assessment by CE-TTE is a novel noninvasive diagnostic tool in the detection of CAV defined as MIT >= 0.5 mm. CFR by CE-TTE may reduce the need for routine IVUS in HT.
2010
Cardiac allograft vasculopathy; coronary flow reserve; diagnosis,
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/22387
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 36
  • ???jsp.display-item.citation.isi??? 32
social impact