In this paper, results of a time performance study of triple gas electron multiplier (GEM) detectors are discussed. This study was driven by an R&D activity on detectors for the Level 0 LHCb muon trigger. However, the results presented in this paper are of more general interest, i.e. for experiments with high rate charged particle triggering. Little interest was given so far to time performance of GEM detectors. Only one group measured double GEM detector time resolution with the Ar/CO2 (70/30) gas mixture. Our study aimed at triple GEM detector optimisation for good time performance through a detailed investigation of the role played by detector geometry, electric fields and gas mixture. The results reported here, in particular when using the gas mixture Ar/CO2/CF4 (60/20/20), considerably improve the time performance discussed in the above-mentioned paper and make the triple GEM detector a promising option for high rate charged particle triggering. (C) 2002 Elsevier Science B.V. All rights reserved.

A triple GEM detector with pad readout for high rate charged particle triggering

Bonivento W;SAITTA, BIAGIO;
2002-01-01

Abstract

In this paper, results of a time performance study of triple gas electron multiplier (GEM) detectors are discussed. This study was driven by an R&D activity on detectors for the Level 0 LHCb muon trigger. However, the results presented in this paper are of more general interest, i.e. for experiments with high rate charged particle triggering. Little interest was given so far to time performance of GEM detectors. Only one group measured double GEM detector time resolution with the Ar/CO2 (70/30) gas mixture. Our study aimed at triple GEM detector optimisation for good time performance through a detailed investigation of the role played by detector geometry, electric fields and gas mixture. The results reported here, in particular when using the gas mixture Ar/CO2/CF4 (60/20/20), considerably improve the time performance discussed in the above-mentioned paper and make the triple GEM detector a promising option for high rate charged particle triggering. (C) 2002 Elsevier Science B.V. All rights reserved.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/37507
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 76
  • ???jsp.display-item.citation.isi??? 66
social impact