OBJECTIVE: To determine the diagnostic performance of International Ovarian Tumor Analysis (IOTA) 'simple' rules for discriminating between benign and malignant adnexal masses. METHODS: A prospective study was performed between January 2011 and June 2012. Eligible patients were women diagnosed with a persistent adnexal mass who presented to the participating centers. Four trainees evaluated the adnexal mass by transvaginal ultrasound under the supervision of an expert examiner. The trainee analyzed the mass according to IOTA simple rules and provided a diagnosis of benign, malignant or inconclusive. All women included in the study underwent surgery and tumor removal in the center of recruitment. Diagnostic performance was assessed by calculating sensitivity, specificity and positive (LR+) and negative (LR-) likelihood ratios. RESULTS: A total of 340 women were included (mean patient age, 42.1 (range, 13-79) years). Of the tumors, 55 (16.2%) were malignant and 285 (83.8%) were benign. The IOTA simple rules could be applied in 270 (79.4%) cases. In these cases, sensitivity was 87.9% (95% CI, 72.4-95.2), specificity 97.5% (95% CI, 94.6-98.8), LR+ 34.7 (95% CI, 15.6-77.3) and LR- 0.12 (95% CI, 0.05-0.31). CONCLUSIONS: Application of the IOTA simple rules yielded acceptable results in terms of specificity in the hands of non-expert examiners. However, with non-expert examiners there was a 12% false-negative rate, which is relatively high

IOTA simple rules for discriminating between benign and malignant adnexal masses: prospective external validation.

SABA, LUCA;GUERRIERO, STEFANO
2013-01-01

Abstract

OBJECTIVE: To determine the diagnostic performance of International Ovarian Tumor Analysis (IOTA) 'simple' rules for discriminating between benign and malignant adnexal masses. METHODS: A prospective study was performed between January 2011 and June 2012. Eligible patients were women diagnosed with a persistent adnexal mass who presented to the participating centers. Four trainees evaluated the adnexal mass by transvaginal ultrasound under the supervision of an expert examiner. The trainee analyzed the mass according to IOTA simple rules and provided a diagnosis of benign, malignant or inconclusive. All women included in the study underwent surgery and tumor removal in the center of recruitment. Diagnostic performance was assessed by calculating sensitivity, specificity and positive (LR+) and negative (LR-) likelihood ratios. RESULTS: A total of 340 women were included (mean patient age, 42.1 (range, 13-79) years). Of the tumors, 55 (16.2%) were malignant and 285 (83.8%) were benign. The IOTA simple rules could be applied in 270 (79.4%) cases. In these cases, sensitivity was 87.9% (95% CI, 72.4-95.2), specificity 97.5% (95% CI, 94.6-98.8), LR+ 34.7 (95% CI, 15.6-77.3) and LR- 0.12 (95% CI, 0.05-0.31). CONCLUSIONS: Application of the IOTA simple rules yielded acceptable results in terms of specificity in the hands of non-expert examiners. However, with non-expert examiners there was a 12% false-negative rate, which is relatively high
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/53868
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 23
  • Scopus 63
  • ???jsp.display-item.citation.isi??? 57
social impact