The consumption of phenol during its oxidation process in an aqueous solution containing ferrous ions and hydrogen peroxide (Fenton process) was studied in a microwave irradiated environment at a frequency of 2.45 GHz and at a power of 3W for different Fe2+ and phenol initial concentrations; the system was maintained at a constant temperature (25 8C). Experimental results were compared to those obtained in the same system and under the same experimental conditions, but in the absence of irradiation, in order to highlight non-thermal microwave magnetic effects on phenol degradation kinetics, as the temperature of the reacting system was strictly controlled and maintained at the fixed value. This comparison highlighted a great promoting effect of microwaves on the reaction rate not due to a thermal effect, resulting in an about tripled phenol consumption reaction rate; about the same increasing ratio was maintained for systems with the same ratio between ferrous ions and phenol initial concentrations. The authors think that coupling low power microwaves with other advanced oxidation processes for phenol removing, like the Fenton process, could be a very promising method, particularly with respect to costs, as energy consumption is very low if compared to the possible advantages.

The enhancing effect of low power microwaves on phenol oxidation by the Fenton process

CARTA, RENZO MARIO SALVATORE;DESOGUS, FRANCESCO
2013-01-01

Abstract

The consumption of phenol during its oxidation process in an aqueous solution containing ferrous ions and hydrogen peroxide (Fenton process) was studied in a microwave irradiated environment at a frequency of 2.45 GHz and at a power of 3W for different Fe2+ and phenol initial concentrations; the system was maintained at a constant temperature (25 8C). Experimental results were compared to those obtained in the same system and under the same experimental conditions, but in the absence of irradiation, in order to highlight non-thermal microwave magnetic effects on phenol degradation kinetics, as the temperature of the reacting system was strictly controlled and maintained at the fixed value. This comparison highlighted a great promoting effect of microwaves on the reaction rate not due to a thermal effect, resulting in an about tripled phenol consumption reaction rate; about the same increasing ratio was maintained for systems with the same ratio between ferrous ions and phenol initial concentrations. The authors think that coupling low power microwaves with other advanced oxidation processes for phenol removing, like the Fenton process, could be a very promising method, particularly with respect to costs, as energy consumption is very low if compared to the possible advantages.
2013
Fenton process, Irradiated environment, Microwaves, Non-thermal effects, Phenol oxidation
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S2213343713001875-main.pdf

Solo gestori archivio

Descrizione: articolo
Tipologia: versione editoriale
Dimensione 503.42 kB
Formato Adobe PDF
503.42 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/91623
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 47
  • ???jsp.display-item.citation.isi??? ND
social impact