An extensive experimental analysis of a two-phase Interleaved PFC Boost converter (I-PFC-B) is presented in this paper. It aims to highlight the most important features of I-PFCB operation, in terms of both performances and Electromagnetic Compatibility (EMC) issues. Therefore, several experimental tests are performed inside an anechoic RF chamber; in particular, Power Factor, Total Harmonic Distortion Factor, Current Crest Factor and energy efficiency are determined at different I-PFC-B output powers. Furthermore, appropriate Conducted and Radiated Emission tests are performed, in accordance with international standards, in order to reveal IPFC-B aptitude as a non-intentional Electromagnetic Interference (EMI) source. The results highlight poor I-PFC-B performances at light loads, as well as potential conducted EMI issues within low and medium frequency ranges.

Performance and EMC Analysis of an Interleaved PFC Boost Converter Topology

SPANO, IVAN LUIGI;MOCCI, ANDREA;SERPI, ALESSANDRO;MARONGIU, IGNAZIO;GATTO, GIANLUCA
2014-01-01

Abstract

An extensive experimental analysis of a two-phase Interleaved PFC Boost converter (I-PFC-B) is presented in this paper. It aims to highlight the most important features of I-PFCB operation, in terms of both performances and Electromagnetic Compatibility (EMC) issues. Therefore, several experimental tests are performed inside an anechoic RF chamber; in particular, Power Factor, Total Harmonic Distortion Factor, Current Crest Factor and energy efficiency are determined at different I-PFC-B output powers. Furthermore, appropriate Conducted and Radiated Emission tests are performed, in accordance with international standards, in order to reveal IPFC-B aptitude as a non-intentional Electromagnetic Interference (EMI) source. The results highlight poor I-PFC-B performances at light loads, as well as potential conducted EMI issues within low and medium frequency ranges.
2014
978-1-4799-6557-1
AC-DC power converters, Conducted and radiated EMI emissions, Electromagnetic compatibility, Interleaved PFC, Power factor correction (PFC), Power quality
File in questo prodotto:
File Dimensione Formato  
P42#2014#UPEC#IEEE_Paper.pdf

Solo gestori archivio

Descrizione: Performance and EMC Analysis of an Interleaved PFC Boost Converter Topology
Tipologia: versione editoriale (VoR)
Dimensione 2.53 MB
Formato Adobe PDF
2.53 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
P42#2014#UPEC#PostPrint.pdf

Solo gestori archivio

Descrizione: Performance and EMC Analysis of an Interleaved PFC Boost Converter Topology (Post Print)
Tipologia: versione post-print (AAM)
Dimensione 2.52 MB
Formato Adobe PDF
2.52 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/107635
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 0
social impact