Goal: To evaluate a novel kind of textile electrodes based on woven fabrics treated with PEDOT:PSS, through an easy fabrication process, testing these electrodes for biopotential recordings. Methods: Fabrication is based on raw fabric soaking in PEDOT: PSS using a second dopant, squeezing and annealing. The electrodes have been tested on human volunteers, in terms of both skin contact impedance and quality of the ECG signals recorded at rest and during physical activity (power spectral density, baseline wandering, QRS detectability, and broadband noise). Results: The electrodes are able to operate in both wet and dry conditions. Dry electrodes are more prone to noise artifacts, especially during physical exercise and mainly due to the unstable contact between the electrode and the skin. Wet (saline) electrodes present a stable and reproducible behavior, which is comparable or better than that of traditional disposable gelled Ag/AgCl electrodes. Conclusion: The achieved results reveal the capability of this kind of electrodes to work without the electrolyte, providing a valuable interface with the skin, due to mixed electronic and ionic conductivity of PEDOT:PSS. These electrodes can be effectively used for acquiring ECG signals. Significance: Textile electrodes based on PEDOT:PSS represent an important milestone in wearable monitoring, as they present an easy and reproducible fabrication process, very good performance in wet and dry (at rest) conditions and a superior level of comfort with respect to textile electrodes proposed so far. This paves the way to their integration into smart garments.

Fully textile, PEDOT:PSS based electrodes for wearable ECG monitoring systems

PANI, DANILO;BARABINO, GIANLUCA;BONFIGLIO, ANNALISA
2016-01-01

Abstract

Goal: To evaluate a novel kind of textile electrodes based on woven fabrics treated with PEDOT:PSS, through an easy fabrication process, testing these electrodes for biopotential recordings. Methods: Fabrication is based on raw fabric soaking in PEDOT: PSS using a second dopant, squeezing and annealing. The electrodes have been tested on human volunteers, in terms of both skin contact impedance and quality of the ECG signals recorded at rest and during physical activity (power spectral density, baseline wandering, QRS detectability, and broadband noise). Results: The electrodes are able to operate in both wet and dry conditions. Dry electrodes are more prone to noise artifacts, especially during physical exercise and mainly due to the unstable contact between the electrode and the skin. Wet (saline) electrodes present a stable and reproducible behavior, which is comparable or better than that of traditional disposable gelled Ag/AgCl electrodes. Conclusion: The achieved results reveal the capability of this kind of electrodes to work without the electrolyte, providing a valuable interface with the skin, due to mixed electronic and ionic conductivity of PEDOT:PSS. These electrodes can be effectively used for acquiring ECG signals. Significance: Textile electrodes based on PEDOT:PSS represent an important milestone in wearable monitoring, as they present an easy and reproducible fabrication process, very good performance in wet and dry (at rest) conditions and a superior level of comfort with respect to textile electrodes proposed so far. This paves the way to their integration into smart garments.
2016
Biomedical electrodes; Electrocardiography; PEDOT:PSS; Textile electrodes; Textile technology
File in questo prodotto:
File Dimensione Formato  
07182320.pdf

Solo gestori archivio

Descrizione: Manoscritto
Tipologia: versione editoriale (VoR)
Dimensione 670.8 kB
Formato Adobe PDF
670.8 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/136774
Citazioni
  • ???jsp.display-item.citation.pmc??? 42
  • Scopus 164
  • ???jsp.display-item.citation.isi??? 145
social impact