This paper compares the performance of medium size Concentrating Solar Power (CSP) plants based on an Organic Rankine Cycle (ORC) power generation unit and using linear Fresnel collectors, thermal oil as heat transfer fluid and two-tank direct and thermocline energy storage systems. The comparative performance analysis was carried out by means of specifically developed simulation models and considering different values of solar multiple and thermal energy storage capacity. The results of the performance assessment demonstrate that if the CSP plant has to be optimized for the highest specific energy production, that is, for the highest solar energy conversion efficiency, two-tank energy storage systems show slightly higher performance than thermocline storage systems. However, the study also demonstrates that thermocline storage systems can be an interesting option to reduce the energy production cost of CSP plants.

Performance comparison of two-tank direct and thermocline thermal energy storage systems for 1MWe class concentrating solar power plants

COCCO, DANIELE;
2015-01-01

Abstract

This paper compares the performance of medium size Concentrating Solar Power (CSP) plants based on an Organic Rankine Cycle (ORC) power generation unit and using linear Fresnel collectors, thermal oil as heat transfer fluid and two-tank direct and thermocline energy storage systems. The comparative performance analysis was carried out by means of specifically developed simulation models and considering different values of solar multiple and thermal energy storage capacity. The results of the performance assessment demonstrate that if the CSP plant has to be optimized for the highest specific energy production, that is, for the highest solar energy conversion efficiency, two-tank energy storage systems show slightly higher performance than thermocline storage systems. However, the study also demonstrates that thermocline storage systems can be an interesting option to reduce the energy production cost of CSP plants.
2015
CSP plants; Linear fresnel collector; Thermal energy storage; Thermocline storage; Energy (all); Pollution
File in questo prodotto:
File Dimensione Formato  
Energy_2015.pdf

Solo gestori archivio

Descrizione: Energy_2015
Tipologia: versione post-print
Dimensione 1.31 MB
Formato Adobe PDF
1.31 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/143327
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 122
  • ???jsp.display-item.citation.isi??? 94
social impact