Spectroflourometric studies on the binding properties of 5-pyridino-2,8-dithia[9](2,9)-1,10-phenanthrolinephane (L) toward La3+, Sm3+, Gd3+, Yb3+, and Nd3+ in methanol solution revealed the occurrence of both 1:1 and 2:1 (ligand/metal) complexation with a stability order of Nd3+ > Yb3+ > Gd3+ > Sm3+ > La3+. Consequently, L was used as a suitable neutral ionophore for the preparation of a novel polymeric membrane-selective electrode for Nd3+ ion. The electrode exhibited a Nernstian response over a wide concentration range (1.0 x 10-6 - 1.0 x 10-2 M) with a low limit of detection of 7.9 x 10-7 M. The electrode possesses a fast response time of <5 s and can be used for at least 9 weeks without observing any considerable deviation. The proposed electrode revealed a very good selectivity for Nd3+ over a wide variety of alkali, alkaline earth, transition, and heavy metal ions, including members of the lanthanide family other than Nd3+. The potentiometric response of the electrode is independent of the pH of test solution in the pH range 4.0-6.5. The proposed electrode was successfully applied to the recovery of Nd3+ ion from tap water samples and, also, as an indicator electrode, in potentiometric titration of neodymium(III) ions.

PVC membrane potentiometric sensor based on 5-pyridino-2,8-dothia[9](2,9)-1,10-phenanthrolinephane for selective determination of neodymium(III)

LIPPOLIS, VITO
2005-01-01

Abstract

Spectroflourometric studies on the binding properties of 5-pyridino-2,8-dithia[9](2,9)-1,10-phenanthrolinephane (L) toward La3+, Sm3+, Gd3+, Yb3+, and Nd3+ in methanol solution revealed the occurrence of both 1:1 and 2:1 (ligand/metal) complexation with a stability order of Nd3+ > Yb3+ > Gd3+ > Sm3+ > La3+. Consequently, L was used as a suitable neutral ionophore for the preparation of a novel polymeric membrane-selective electrode for Nd3+ ion. The electrode exhibited a Nernstian response over a wide concentration range (1.0 x 10-6 - 1.0 x 10-2 M) with a low limit of detection of 7.9 x 10-7 M. The electrode possesses a fast response time of <5 s and can be used for at least 9 weeks without observing any considerable deviation. The proposed electrode revealed a very good selectivity for Nd3+ over a wide variety of alkali, alkaline earth, transition, and heavy metal ions, including members of the lanthanide family other than Nd3+. The potentiometric response of the electrode is independent of the pH of test solution in the pH range 4.0-6.5. The proposed electrode was successfully applied to the recovery of Nd3+ ion from tap water samples and, also, as an indicator electrode, in potentiometric titration of neodymium(III) ions.
2005
Neodymium; Macrocycle; phenanthroline; Ion selective electrode
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/15222
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 65
  • ???jsp.display-item.citation.isi??? 63
social impact