OBJECTIVE: To evaluate the feasibility and safety of office hysteroscopic metroplasty using a 980nm diode laser. STUDY DESIGN: 18 patients were treated for septate uterus between 2013 and 2016. The indications for hysteroscopic metroplasty were recurrent abortion in 11 of the women and primary infertility in the other seven. We used a 5mm-office hysteroscope with a diode laser fibre. After exploration of the cavity, the septum was divided with use of the laser fibre. RESULTS: Operating time was 13,16±1,33min. Intraoperative pain was 3,05±0,72. No intraoperative or postoperative complications were observed. Follow-up performed 2 months after the hysteroscopic metroplasty confirmed the complete removal of the septum and no evidence of intrauterine synechiae. CONCLUSION: Office hysteroscopic metroplasty with use of a diode laser is safe and feasible; we believe that vaporization of the septum with a diode laser could reduce the formation of adhesions and consequently reduce the occurrence of septum persistence.

Hysteroscopic metroplasty for the septate uterus with diode laser: a pilot study

ANGIONI, STEFANO
2016-01-01

Abstract

OBJECTIVE: To evaluate the feasibility and safety of office hysteroscopic metroplasty using a 980nm diode laser. STUDY DESIGN: 18 patients were treated for septate uterus between 2013 and 2016. The indications for hysteroscopic metroplasty were recurrent abortion in 11 of the women and primary infertility in the other seven. We used a 5mm-office hysteroscope with a diode laser fibre. After exploration of the cavity, the septum was divided with use of the laser fibre. RESULTS: Operating time was 13,16±1,33min. Intraoperative pain was 3,05±0,72. No intraoperative or postoperative complications were observed. Follow-up performed 2 months after the hysteroscopic metroplasty confirmed the complete removal of the septum and no evidence of intrauterine synechiae. CONCLUSION: Office hysteroscopic metroplasty with use of a diode laser is safe and feasible; we believe that vaporization of the septum with a diode laser could reduce the formation of adhesions and consequently reduce the occurrence of septum persistence.
2016
Diode laser; Hysteroscopy; Metroplasty; Uterine septum
File in questo prodotto:
File Dimensione Formato  
Nappi Eur J Ob Gyn Biol Rep 2016.pdf

Solo gestori archivio

Tipologia: versione editoriale
Dimensione 339.46 kB
Formato Adobe PDF
339.46 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/180290
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 30
  • ???jsp.display-item.citation.isi??? 23
social impact