Background: In young patients with osteonecrosis of the femoral head (ONFH), short-stem total hip arthroplasty (THA) could allow a potential advantage in preserving metaphyseal bone-stock, when revision surgery might become necessary. However, only a few studies have evaluated the outcome of short-stem THAs in ONFH. We reviewed the prospectively collected data of a cementless partial neck-retaining short-stem with ceramic-on-ceramic bearings in ONFH patients. Methods: Thirty patients (37 hips) younger than 60 years (mean age at surgery, 51.5 years) underwent THA with the NANOS (R) stem (Smith and Nephew, Marl, Germany) from January 2006 to December 2012. All patients received a 32-mm or 36 mm ceramic femoral head. Harris hip score, WOMAC and UCLA activity score were recorded. Postoperative radiographs were evaluated for bone-implant fixation and osteolysis. Further analysis correlated clinical findings with implants characteristics and patient demographics at mean 5.6 years' follow-up (range, 3-10 years). Results: The clinical and functional results improved significantly (p < 0.001). At latest follow-up, mean HHS, WOMAC, and UCLA activity scores were 90 (range, 71-100), 94 (range, 76-100), and 6.3 (range, 4-10) points, respectively. The diameter of the femoral head did not influence the clinical outcome (p = 0.661). All hips showed bone ingrowth fixation of the acetabular and femoral components. No patients showed osteolysis. No revision for any reason was performed during the study period. Conclusions: The excellent clinical results and fixation pattern at mean 5.6 years' follow-up reveal this implant as a reliable option in advanced stage of ONFH either. Further investigations are crucial to determine the long-term durability and to assess whether the association of ceramic-on-ceramic bearings, can be useful to achieve longer survivorship and lower complications rates.

Short stem total hip arthroplasty for osteonecrosis of the femoral head in patients 60 years or younger: A 3- to 10-year follow-up study

CAPONE, ANTONIO;BIENATI, FABRIZIO;TORCHIA, STEFANIA;PODDA, DANIELE;MARONGIU, GIUSEPPE
2017-01-01

Abstract

Background: In young patients with osteonecrosis of the femoral head (ONFH), short-stem total hip arthroplasty (THA) could allow a potential advantage in preserving metaphyseal bone-stock, when revision surgery might become necessary. However, only a few studies have evaluated the outcome of short-stem THAs in ONFH. We reviewed the prospectively collected data of a cementless partial neck-retaining short-stem with ceramic-on-ceramic bearings in ONFH patients. Methods: Thirty patients (37 hips) younger than 60 years (mean age at surgery, 51.5 years) underwent THA with the NANOS (R) stem (Smith and Nephew, Marl, Germany) from January 2006 to December 2012. All patients received a 32-mm or 36 mm ceramic femoral head. Harris hip score, WOMAC and UCLA activity score were recorded. Postoperative radiographs were evaluated for bone-implant fixation and osteolysis. Further analysis correlated clinical findings with implants characteristics and patient demographics at mean 5.6 years' follow-up (range, 3-10 years). Results: The clinical and functional results improved significantly (p < 0.001). At latest follow-up, mean HHS, WOMAC, and UCLA activity scores were 90 (range, 71-100), 94 (range, 76-100), and 6.3 (range, 4-10) points, respectively. The diameter of the femoral head did not influence the clinical outcome (p = 0.661). All hips showed bone ingrowth fixation of the acetabular and femoral components. No patients showed osteolysis. No revision for any reason was performed during the study period. Conclusions: The excellent clinical results and fixation pattern at mean 5.6 years' follow-up reveal this implant as a reliable option in advanced stage of ONFH either. Further investigations are crucial to determine the long-term durability and to assess whether the association of ceramic-on-ceramic bearings, can be useful to achieve longer survivorship and lower complications rates.
2017
osteonecrosis of the femoral head; hip arthroplasty; short stems; ceramic on ceramic bearings
File in questo prodotto:
File Dimensione Formato  
Capone_Short stem total.pdf

accesso aperto

Tipologia: versione editoriale
Dimensione 603.02 kB
Formato Adobe PDF
603.02 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/219188
Citazioni
  • ???jsp.display-item.citation.pmc??? 14
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 37
social impact