The present work reports the interaction of various vitamin B6cofactors with the red emitting glutathione stabilized copper nanoclusters (GSH-CuNCs). Addition of pyridoxamine (PM) resulted a new turn-on band at 410 nm due to the possible adsorption over the surface of GSH-CuNCs. The nano-assembly PM-GSH-CuNCs was applied for the selective detection of nitro-aromatic compounds. Upon addition of picric acid (PA), the fluorescence of PM-GSH-CuNCs was selectively quenched at 410 nm and ~ 625 nm among the other tested nitro-aromatic compounds. With a linearity range from 9.9 μM to 43 μM, the concentration of PA can be detected down to 2.74 μM. The high selectivity exhibited by the nano-assembly allows to detect PA in real samples like tap water, river water and matchstick. Advantageously, the nano-assembly PM-GSH-CuNCs was chemically adsorbed over the cellulosic strips and applied for the naked-eye detection of PA down to 1 μM.

Pyridoxamine driven selective turn-off detection of picric acid using glutathione stabilized fluorescent copper nanoclusters and its applications with chemically modified cellulose strips

Crisponi, Guido;
2018-01-01

Abstract

The present work reports the interaction of various vitamin B6cofactors with the red emitting glutathione stabilized copper nanoclusters (GSH-CuNCs). Addition of pyridoxamine (PM) resulted a new turn-on band at 410 nm due to the possible adsorption over the surface of GSH-CuNCs. The nano-assembly PM-GSH-CuNCs was applied for the selective detection of nitro-aromatic compounds. Upon addition of picric acid (PA), the fluorescence of PM-GSH-CuNCs was selectively quenched at 410 nm and ~ 625 nm among the other tested nitro-aromatic compounds. With a linearity range from 9.9 μM to 43 μM, the concentration of PA can be detected down to 2.74 μM. The high selectivity exhibited by the nano-assembly allows to detect PA in real samples like tap water, river water and matchstick. Advantageously, the nano-assembly PM-GSH-CuNCs was chemically adsorbed over the cellulosic strips and applied for the naked-eye detection of PA down to 1 μM.
2018
Chemically-modified cellulose strips; Fluorescent copper nanoclusters; Picric acid; Pyridoxamine; Turn-off sensor; Biotechnology; Biophysics; Biomedical engineering; Electrochemistry
File in questo prodotto:
File Dimensione Formato  
Biosensors&Bioelectronics 2018.pdf

Solo gestori archivio

Tipologia: versione editoriale
Dimensione 1.21 MB
Formato Adobe PDF
1.21 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/233887
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 73
  • ???jsp.display-item.citation.isi??? 71
social impact