Background: The DIEAP flap has gained popularity for breast reconstruction worldwide. Despite DIEAP flap arterial anatomy being well known, venous congestion is still an important complication and the literature on DIEAP flap venous anatomy is lacking. Venous drainage is less predictable and research on venous perforators is of increasing interest. The aim of this study was to investigate the anatomical distribution, diameters and relationships between arterial and venous perforators and their source vessels using Duplex ultrasonography, in order to evaluate the potential benefits of pre-operative evaluation of DIEAP flap venous perforators. Methods: Prospectively, 140 patients undergoing DIEAP flap breast reconstruction, were pre-operatively assessed using Duplex ultrasonography for location and diameter of arterial and venous perforators, DIEA, DIEV, and SIEV. Perforators were plotted laterally and inferiorly from the umbilicus. Means were compared using t-tests. Pearson's correlation coefficients were calculated. Results: We identified 702 arterial and 355 venous perforators in 280 lower hemi-abdomens. No venous perforators were identified in 9 (6.5%) patients; none on the right in 25 (17.9%) and none on the left in 36 (25.7%). Venous perforators were larger on the right (p = 0.031) but DIEV and SIEV diameters were not statistically different on either sides. The diameters of DIEA, DIEV, perforating arteries and veins were correlated, but unrelated to the diameter of the SIEV. When a medium/large perforator vein is identified first, there is a 93.5% chance of finding an associated medium/large perforator artery; this reduces to 69.8% when a medium/large perforator artery is first identified. Conclusions: There is no correlation between the sizes of perforator veins and DIEV, and the size of the SIEV. Our data suggests that first identifying a medium/large venous perforator increases the chances of finding a better suitable perforator complex. Pre-operative evaluation of venous perforators may be of great interest for its potential clinical benefits.

Venous perforators in DIEAP flaps: An observational anatomical study using duplex ultrasonography

Figus, Andrea
;
2012-01-01

Abstract

Background: The DIEAP flap has gained popularity for breast reconstruction worldwide. Despite DIEAP flap arterial anatomy being well known, venous congestion is still an important complication and the literature on DIEAP flap venous anatomy is lacking. Venous drainage is less predictable and research on venous perforators is of increasing interest. The aim of this study was to investigate the anatomical distribution, diameters and relationships between arterial and venous perforators and their source vessels using Duplex ultrasonography, in order to evaluate the potential benefits of pre-operative evaluation of DIEAP flap venous perforators. Methods: Prospectively, 140 patients undergoing DIEAP flap breast reconstruction, were pre-operatively assessed using Duplex ultrasonography for location and diameter of arterial and venous perforators, DIEA, DIEV, and SIEV. Perforators were plotted laterally and inferiorly from the umbilicus. Means were compared using t-tests. Pearson's correlation coefficients were calculated. Results: We identified 702 arterial and 355 venous perforators in 280 lower hemi-abdomens. No venous perforators were identified in 9 (6.5%) patients; none on the right in 25 (17.9%) and none on the left in 36 (25.7%). Venous perforators were larger on the right (p = 0.031) but DIEV and SIEV diameters were not statistically different on either sides. The diameters of DIEA, DIEV, perforating arteries and veins were correlated, but unrelated to the diameter of the SIEV. When a medium/large perforator vein is identified first, there is a 93.5% chance of finding an associated medium/large perforator artery; this reduces to 69.8% when a medium/large perforator artery is first identified. Conclusions: There is no correlation between the sizes of perforator veins and DIEV, and the size of the SIEV. Our data suggests that first identifying a medium/large venous perforator increases the chances of finding a better suitable perforator complex. Pre-operative evaluation of venous perforators may be of great interest for its potential clinical benefits.
2012
Breast; DIEAP; DIEP; Doppler; Duplex; Perforator; Reconstruction; SIEA; SIEV; Abdominal wall; Adolescent; Adult; Aged; Arteries; Female; Humans; Mammaplasty; Middle aged; Models, anatomic; Prospective studies; Rectus Abdominis; Surgical Ffaps; Ultrasonography, Doppler, Duplex; Veins; Young adult; Surgery
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S1748681512001118-main.pdf

Solo gestori archivio

Tipologia: versione editoriale
Dimensione 1.21 MB
Formato Adobe PDF
1.21 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/240494
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 21
social impact