This study was conducted to develop a screen-printed approach for the fabrication of textile electrodes and analyse their characteristic features for use as electrocardiography (ECG) signal sensors. The electrodes were obtained by printing poly(3,4-ethylenedioxythiophene) doped with poly(4-styrenesulfonate) (PEDOT:PSS) organic bio-compatible polymer-based ink on a finished fabric using a polyester mesh with 43 lines/cm. The physical–chemical properties of the polymer solution were varied to obtain a simple and reproducible fabrication process and a good electrode performance simultaneously. The electrode properties were first assessed by a benchtop measurement instrument and then on human subjects. Several tests under different conditions, for instance, by adding liquid and solid electrolytes, revealed that the electrodes possess the majority of characteristics required by the ANSI/AAMI EC12:2000 standard for gelled ECG electrodes. Furthermore, the benchtop measurements demonstrated that these electrodes preserve their electrical properties and functionality even after several washing cycles (performed under mild conditions), while they suffered physical stretching. While using some electrolytes, the skin contact impedance and the features extracted from the physiological signals were found to be highly similar to those obtained with disposable gelled Ag/AgCl electrodes ( > 0.99). Through the proposed fabrication process, it is possible to change the electrical properties of a specific region of a finished fabric or a garment with an excellent geometrical resolution. This opportunity, along with the obtained results in terms of the electrical characteristics as ECG electrodes, indicates that the proposed approach could possibly be adopted in the future for the development of smart garments that could comfortably detect ECG signals.

Design and characterisation of screen-printed textile electrodes for ECG monitoring

Andrea Achilli
Primo
;
Annalisa Bonfiglio
Secondo
;
Danilo Pani
Ultimo
2018-01-01

Abstract

This study was conducted to develop a screen-printed approach for the fabrication of textile electrodes and analyse their characteristic features for use as electrocardiography (ECG) signal sensors. The electrodes were obtained by printing poly(3,4-ethylenedioxythiophene) doped with poly(4-styrenesulfonate) (PEDOT:PSS) organic bio-compatible polymer-based ink on a finished fabric using a polyester mesh with 43 lines/cm. The physical–chemical properties of the polymer solution were varied to obtain a simple and reproducible fabrication process and a good electrode performance simultaneously. The electrode properties were first assessed by a benchtop measurement instrument and then on human subjects. Several tests under different conditions, for instance, by adding liquid and solid electrolytes, revealed that the electrodes possess the majority of characteristics required by the ANSI/AAMI EC12:2000 standard for gelled ECG electrodes. Furthermore, the benchtop measurements demonstrated that these electrodes preserve their electrical properties and functionality even after several washing cycles (performed under mild conditions), while they suffered physical stretching. While using some electrolytes, the skin contact impedance and the features extracted from the physiological signals were found to be highly similar to those obtained with disposable gelled Ag/AgCl electrodes ( > 0.99). Through the proposed fabrication process, it is possible to change the electrical properties of a specific region of a finished fabric or a garment with an excellent geometrical resolution. This opportunity, along with the obtained results in terms of the electrical characteristics as ECG electrodes, indicates that the proposed approach could possibly be adopted in the future for the development of smart garments that could comfortably detect ECG signals.
2018
Screen-printed electrodes, ECG, Textile electrodes, PEDOT:PSS
File in questo prodotto:
File Dimensione Formato  
sensors.pdf

Solo gestori archivio

Descrizione: manoscritto
Tipologia: versione editoriale
Dimensione 2.51 MB
Formato Adobe PDF
2.51 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/241828
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 54
  • ???jsp.display-item.citation.isi??? 46
social impact