The aim of this paper is the study of the air quality in narrow urban canyons (ratio of the distance between two buildings to the building height less than or equal to one). This has been done by investigating two key points. The first one is the investigation of the modifications that the roof shape induces in the flow and turbulence, through the comparison of velocity fields, turbulence characteristics and air exchanges between the urban canyon and the outer flow in arrays of buildings with flat and pitched roofs. The second one is the assessment of the capability of a RANS model to correctly simulate the flow, through the comparison with laboratory water-channel simulations. Among the analysed quantities, the vertical air exchange rate ACH measures the rate of air removal from a street canyon. Results show that the pitched roof strongly modifies the flow and increases the turbulence and the air exchange between the canyon and the external flow, highlighting how the choice of the roof shape can be meaningful for building design, planning strategies and regulatory purposes.

The air quality in narrow two-dimensional urban canyons with pitched and flat roof buildings

Simone Ferrari
Primo
;
Maria Grazia Badas;GARAU, MICHELA;Alessandro Seoni;Giorgio Querzoli
2017-01-01

Abstract

The aim of this paper is the study of the air quality in narrow urban canyons (ratio of the distance between two buildings to the building height less than or equal to one). This has been done by investigating two key points. The first one is the investigation of the modifications that the roof shape induces in the flow and turbulence, through the comparison of velocity fields, turbulence characteristics and air exchanges between the urban canyon and the outer flow in arrays of buildings with flat and pitched roofs. The second one is the assessment of the capability of a RANS model to correctly simulate the flow, through the comparison with laboratory water-channel simulations. Among the analysed quantities, the vertical air exchange rate ACH measures the rate of air removal from a street canyon. Results show that the pitched roof strongly modifies the flow and increases the turbulence and the air exchange between the canyon and the external flow, highlighting how the choice of the roof shape can be meaningful for building design, planning strategies and regulatory purposes.
2017
Narrow urban canyon; Air quality; Natural ventilation; Pitched roof; RANS simulation; Laboratory simulation
File in questo prodotto:
File Dimensione Formato  
2017_RI_Ferrari_etal_IJEP.pdf

Solo gestori archivio

Tipologia: versione editoriale (VoR)
Dimensione 891.76 kB
Formato Adobe PDF
891.76 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
Ferrari_etal_ijep_2017_preprint.pdf

accesso aperto

Tipologia: versione pre-print
Dimensione 930.49 kB
Formato Adobe PDF
930.49 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/242775
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 13
social impact