Engineering design of timber structures in fire conditions is crucial to ensure high safety levels. Wood is subjected to degradation under fire exposure therefore its thermal and mechanical behaviours change. Timber design must take the decrease of timber performance into account to calculate structural elements that can carry external loads also if exposed to high temperatures. Analytical and numerical approaches can be adopted in fire design practice. This research investigates the fire behaviour of laminated veneer lumber elements and cross-laminated timber panels. The study focused on some research questions regarding the fire resistance of unprotected and protected timber structural elements, the possibility to predict accurately the fire behaviour of timber elements through numerical modelling, and the accuracy of analytical estimations of fire resistance using simplified design methods. Experimental tests of small and large specimens exposed to fire on one or more sides and subjected to different types and levels of load were performed. The results highlight the good performance of timber structural elements in fire conditions. The collected data were used to validate two- and three-dimensional models implemented in the general purpose finite element code Abaqus. Thermal and mechanical analyses were carried out to estimate the temperature distribution within unprotected and protected cross-sections of different sizes, the fire resistance and the displacement of timber elements loaded in-plane and out-of-plane. Further, parametric studies assuming different timber properties-temperature relationships were also performed. The proposed numerical modelling can be used to investigate the fire behaviour of timber members made of other wood-based products and subjected to different loads and fire conditions. Experimental and numerical results were compared with analytical predictions obtained by using simplified design methods proposed by current codes of practice and recent research proposals. Numerical and analytical methods provide overall acceptable estimations of fire behaviour of timber members, especially considering the high variability that characterizes the wood material and the experimental tests, in particular the fire tests.

Fire resistance of Laminated Veneer Lumber (LVL) and Cross-Laminated Timber (XLAM) elements

-
2012-03-20

Abstract

Engineering design of timber structures in fire conditions is crucial to ensure high safety levels. Wood is subjected to degradation under fire exposure therefore its thermal and mechanical behaviours change. Timber design must take the decrease of timber performance into account to calculate structural elements that can carry external loads also if exposed to high temperatures. Analytical and numerical approaches can be adopted in fire design practice. This research investigates the fire behaviour of laminated veneer lumber elements and cross-laminated timber panels. The study focused on some research questions regarding the fire resistance of unprotected and protected timber structural elements, the possibility to predict accurately the fire behaviour of timber elements through numerical modelling, and the accuracy of analytical estimations of fire resistance using simplified design methods. Experimental tests of small and large specimens exposed to fire on one or more sides and subjected to different types and levels of load were performed. The results highlight the good performance of timber structural elements in fire conditions. The collected data were used to validate two- and three-dimensional models implemented in the general purpose finite element code Abaqus. Thermal and mechanical analyses were carried out to estimate the temperature distribution within unprotected and protected cross-sections of different sizes, the fire resistance and the displacement of timber elements loaded in-plane and out-of-plane. Further, parametric studies assuming different timber properties-temperature relationships were also performed. The proposed numerical modelling can be used to investigate the fire behaviour of timber members made of other wood-based products and subjected to different loads and fire conditions. Experimental and numerical results were compared with analytical predictions obtained by using simplified design methods proposed by current codes of practice and recent research proposals. Numerical and analytical methods provide overall acceptable estimations of fire behaviour of timber members, especially considering the high variability that characterizes the wood material and the experimental tests, in particular the fire tests.
20-mar-2012
Abaqus
cross laminated timber
elementi lignei
finite element modelling
fire tests
laminated veneer lumber
legno lamellare incrociato
legno microlamellare
modellazione agli elementi finiti
prove al fuoco
resistenza al fuoco
timber elements
Menis, Agnese
File in questo prodotto:
File Dimensione Formato  
Agnese_MENIS_PhD_Thesis.pdf

accesso aperto

Tipologia: Tesi di dottorato
Dimensione 10.87 MB
Formato Adobe PDF
10.87 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/266138
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact