Laboratory corrosion and scaling testing of metallic materials exposed in high temperature and pressure environments generally involves complex, multi-instrument measurement setups. Here, we present a setup including an autoclave that is instrumented for in-situ electrochemical testing and that contains a ZrO2-based solid-state pH electrode and devices for temperature control and solution stirring. We show results highlighting the importance of adequate pre-calibration of the pH measurement, due to the hysteresis depending on temperature sweep. Additionally, we illustrate how interfacing the autoclave and the electrochemical cell to measuring and controlling instruments, using different data communication interfaces, can create ground loops. These ground loop interferences can introduce significant errors in the measurement, such as a potential shift of >100 mV. In complex, multi-instrument setups, a complete understanding of ground loops may often be difficult. Thus, we recommend systematic checks to identify the ground loops and we propose measures to avoid them.

A setup for electrochemical corrosion testing at elevated temperature and pressure

Bernhard Elsener
Ultimo
Writing – Review & Editing
2020-01-01

Abstract

Laboratory corrosion and scaling testing of metallic materials exposed in high temperature and pressure environments generally involves complex, multi-instrument measurement setups. Here, we present a setup including an autoclave that is instrumented for in-situ electrochemical testing and that contains a ZrO2-based solid-state pH electrode and devices for temperature control and solution stirring. We show results highlighting the importance of adequate pre-calibration of the pH measurement, due to the hysteresis depending on temperature sweep. Additionally, we illustrate how interfacing the autoclave and the electrochemical cell to measuring and controlling instruments, using different data communication interfaces, can create ground loops. These ground loop interferences can introduce significant errors in the measurement, such as a potential shift of >100 mV. In complex, multi-instrument setups, a complete understanding of ground loops may often be difficult. Thus, we recommend systematic checks to identify the ground loops and we propose measures to avoid them.
2020
Autoclave; Corrosion; Data communication interface; Ground loop; pH electrode; Potentiostat
File in questo prodotto:
File Dimensione Formato  
Measurements_Ana.pdf

Solo gestori archivio

Tipologia: versione editoriale (VoR)
Dimensione 2.16 MB
Formato Adobe PDF
2.16 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/283300
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 4
social impact