Purpose: To investigate the variation in the quantification of the carotid degree of stenosis (DoS) with a dual energy computed tomography (CT), using different energy levels during the image reconstruction. Methods: In this retrospective study, 53 subjects (37 males; mean age 67 ± 11 years; age range 47–83 years) studied with a multi-energy CT scanner were included. Datasets were reconstructed on a dedicated workstation and from the CT raw data multiple datasets were generated at the following monochromatic energy levels: 66, 70, 77, and 86 kilo-electronvolt (keV). Two radiologists independently performed all measurements for quantification of the degree of stenosis. Wilcoxon test was used to test the differences between the Hounsifield unit (HU) values in the plaques at different keV. Results: The Wilcoxon analysis showed a statistically significant difference (p = 0.001) in the DoS assessment among the different keVs selected. The Bland-Altman analysis showed that the DoS difference had a linear relation with the keV difference (the bigger is the difference in keV, the bigger is the variation in DoS) and that for different keVs, the difference in DoS is reduced with its increase. Conclusion: A standardization in the use of the energy level during the image reconstruction should be considered.

Variation of degree of stenosis quantification using different energy level with dual energy CT scanner

Saba L.
Primo
;
Lavra F.;
2019-01-01

Abstract

Purpose: To investigate the variation in the quantification of the carotid degree of stenosis (DoS) with a dual energy computed tomography (CT), using different energy levels during the image reconstruction. Methods: In this retrospective study, 53 subjects (37 males; mean age 67 ± 11 years; age range 47–83 years) studied with a multi-energy CT scanner were included. Datasets were reconstructed on a dedicated workstation and from the CT raw data multiple datasets were generated at the following monochromatic energy levels: 66, 70, 77, and 86 kilo-electronvolt (keV). Two radiologists independently performed all measurements for quantification of the degree of stenosis. Wilcoxon test was used to test the differences between the Hounsifield unit (HU) values in the plaques at different keV. Results: The Wilcoxon analysis showed a statistically significant difference (p = 0.001) in the DoS assessment among the different keVs selected. The Bland-Altman analysis showed that the DoS difference had a linear relation with the keV difference (the bigger is the difference in keV, the bigger is the variation in DoS) and that for different keVs, the difference in DoS is reduced with its increase. Conclusion: A standardization in the use of the energy level during the image reconstruction should be considered.
2019
Carotid artery; CT; Dual energy CT; Aged; Aged, 80 and over; Carotid Stenosis; Female; Humans; Male; Middle Aged; Radiographic Image Interpretation, Computer-Assisted; Radiography, Dual-Energy Scanned Projection; Retrospective Studies; Tomography, X-Ray Computed
File in questo prodotto:
File Dimensione Formato  
saba2018.pdf

Solo gestori archivio

Tipologia: versione editoriale (VoR)
Dimensione 1.21 MB
Formato Adobe PDF
1.21 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/283905
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 4
social impact