Objective To evaluate the influence of the electrode placement on hearing performance in adult patients who were simultaneously and bilaterally cochlear implanted. Study Design Case series with planned data collection. Setting Tertiary referral university centers. Subjects and Methods The postoperative computed tomography scan was studied for 19 patients who were simultaneously and bilaterally implanted with a long straight electrode array. The size of the cochlea was measured in consideration of the major cochlear diameter and cochlear height. The electrode-to-modiolus distance for the electrodes positioned at 180 and 360 degrees and the angular depth of insertion of the array were also measured. Speech perception was assessed at 1 and 5 years postimplantation with disyllabic word lists in quiet and in noise, with the speech coming from the front and a background noise (cocktail party) coming from 5 loudspeakers. Results At 1 year postimplantation, the electrode-to-modiolus distance at 180 degrees was correlated with the speech perception scores in both quiet and noise. In patients with a full electrode insertion, no correlation was found between the angular depth of insertion and hearing performance. The speech perception scores in noise gradually declined as a function of the number of inserted and active electrodes. No relationship between electrode position and speech perception scores was found at 5 years postimplantation. Conclusion In adult patients who were simultaneously and bilaterally implanted, the use of a long straight array, the full electrode array insertion, and the proximity to the modiolus might be determining factors to obtain the best speech performance at 1 year, without influence on the speech perception scores after long-term use.

The role of electrode placement in bilateral simultaneously cochlear-implanted adult patients

De Seta D.
Primo
;
2016-01-01

Abstract

Objective To evaluate the influence of the electrode placement on hearing performance in adult patients who were simultaneously and bilaterally cochlear implanted. Study Design Case series with planned data collection. Setting Tertiary referral university centers. Subjects and Methods The postoperative computed tomography scan was studied for 19 patients who were simultaneously and bilaterally implanted with a long straight electrode array. The size of the cochlea was measured in consideration of the major cochlear diameter and cochlear height. The electrode-to-modiolus distance for the electrodes positioned at 180 and 360 degrees and the angular depth of insertion of the array were also measured. Speech perception was assessed at 1 and 5 years postimplantation with disyllabic word lists in quiet and in noise, with the speech coming from the front and a background noise (cocktail party) coming from 5 loudspeakers. Results At 1 year postimplantation, the electrode-to-modiolus distance at 180 degrees was correlated with the speech perception scores in both quiet and noise. In patients with a full electrode insertion, no correlation was found between the angular depth of insertion and hearing performance. The speech perception scores in noise gradually declined as a function of the number of inserted and active electrodes. No relationship between electrode position and speech perception scores was found at 5 years postimplantation. Conclusion In adult patients who were simultaneously and bilaterally implanted, the use of a long straight array, the full electrode array insertion, and the proximity to the modiolus might be determining factors to obtain the best speech performance at 1 year, without influence on the speech perception scores after long-term use.
2016
Angular depth of insertion; Bilateral implantation; Cochlear implant; Cochlear size; Electrode position; Speech perception; Adult; Aged; Cochlear implantation; Female; Hearing tests; Humans; Male; Middle aged; Tomography, X-ray computed; Treatment outcome; Cochlear implants; Electrodes, implanted
File in questo prodotto:
File Dimensione Formato  
De_Seta_2016_The_Role_of.pdf

accesso aperto

Tipologia: versione pre-print
Dimensione 902.62 kB
Formato Adobe PDF
902.62 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/284262
Citazioni
  • ???jsp.display-item.citation.pmc??? 16
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 26
social impact