The combination of structural and thermal eciency is a new frontier in civil engineering. Indeed, the retrofitting strategies should optimize costs and technical solutions from these two points of view. If a technical solution is able to provide an improvement of both structural and energetic behavior, then the utility of the intervention can better justify the economic investment. In this paper, a meso-scale approach (i.e., façade-scale) for integrated interventions applied on masonry façades is proposed. The structural performance of the façade is evaluated by considering base shear and ductility of the structural element through non-linear static analyses. Moreover, the thermal indicator, that is the thermal transmittance, is computed with a simplified approach in terms of an equivalent wall, taking into account the role of the windows and doors of the façade. As proof of concept, the procedure is applied to a façade of an existing masonry building. Economic and environmental iso-cost curves are obtained to tune the interventions conceived for a real case study, analyzing the benefit oered by dierent retrofitting solutions.
Integrated Cost-Analysis Approach for Seismic and Thermal Improvement of Masonry Building Façades
Mauro SassuUltimo
Conceptualization
2020-01-01
Abstract
The combination of structural and thermal eciency is a new frontier in civil engineering. Indeed, the retrofitting strategies should optimize costs and technical solutions from these two points of view. If a technical solution is able to provide an improvement of both structural and energetic behavior, then the utility of the intervention can better justify the economic investment. In this paper, a meso-scale approach (i.e., façade-scale) for integrated interventions applied on masonry façades is proposed. The structural performance of the façade is evaluated by considering base shear and ductility of the structural element through non-linear static analyses. Moreover, the thermal indicator, that is the thermal transmittance, is computed with a simplified approach in terms of an equivalent wall, taking into account the role of the windows and doors of the façade. As proof of concept, the procedure is applied to a façade of an existing masonry building. Economic and environmental iso-cost curves are obtained to tune the interventions conceived for a real case study, analyzing the benefit oered by dierent retrofitting solutions.File | Dimensione | Formato | |
---|---|---|---|
buildings-10-00143.pdf
accesso aperto
Descrizione: Articolo
Tipologia:
versione editoriale (VoR)
Dimensione
3 MB
Formato
Adobe PDF
|
3 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.