Herein, a nanocomposite consisting of graphene quantum dots, a deep eutectic solvent and carboxyl functionalized multiwall carbon nanotubes (GQDs + DES + MWCNTs-COOH) was prepared. After electropolymerization of l-arginine on the surface of a glassy carbon electrode modified with the GQDs + DES + MWCNTs-COOH nanocomposite, an electrochemical sensor was fabricated. The morphology of the GQDs + DES + MWCNTs-COOH/PARG surface was characterized via field emission electron microscopy. The sensor allowed excellent performance to be obtained for the analytical monitoring of paracetamol and its metabolite 4-aminophenol. Under the optimal conditions, the prepared electrochemical sensor exhibited wide linear dynamic ranges from 0.030 to 110 μmol L-1 and 0.050 to 100 μmol L-1 for paracetamol and 4-aminophenol, respectively. Moreover, the detection limits were 0.010 μmol L-1 and 0.017 μmol L-1, for paracetamol and 4-aminophenol, respectively. The practical applicability of the constructed sensor was explored by the determination of both compounds in human fluid samples and acceptable results were obtained.

An amplified electrochemical sensor employing a polymeric film and graphene quantum dots/multiwall carbon nanotubes in a deep eutectic solvent for sensitive analysis of paracetamol and 4-aminophenol

Salis, Andrea
Penultimo
;
2020-01-01

Abstract

Herein, a nanocomposite consisting of graphene quantum dots, a deep eutectic solvent and carboxyl functionalized multiwall carbon nanotubes (GQDs + DES + MWCNTs-COOH) was prepared. After electropolymerization of l-arginine on the surface of a glassy carbon electrode modified with the GQDs + DES + MWCNTs-COOH nanocomposite, an electrochemical sensor was fabricated. The morphology of the GQDs + DES + MWCNTs-COOH/PARG surface was characterized via field emission electron microscopy. The sensor allowed excellent performance to be obtained for the analytical monitoring of paracetamol and its metabolite 4-aminophenol. Under the optimal conditions, the prepared electrochemical sensor exhibited wide linear dynamic ranges from 0.030 to 110 μmol L-1 and 0.050 to 100 μmol L-1 for paracetamol and 4-aminophenol, respectively. Moreover, the detection limits were 0.010 μmol L-1 and 0.017 μmol L-1, for paracetamol and 4-aminophenol, respectively. The practical applicability of the constructed sensor was explored by the determination of both compounds in human fluid samples and acceptable results were obtained.
File in questo prodotto:
File Dimensione Formato  
d0nj03371e.pdf

Solo gestori archivio

Descrizione: articolo principale
Tipologia: versione editoriale (VoR)
Dimensione 4.89 MB
Formato Adobe PDF
4.89 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/296752
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 20
social impact