The feasibility and cost-effectiveness of hydrogen-based microgrids in facilities, such as public buildings and small- and medium-sized enterprises, provided by photovoltaic (PV) plants and characterized by low electric demand during weekends, were investigated in this paper. Starting from the experience of the microgrid being built at the Renewable Energy Facility of Sardegna Ricerche (Italy), which, among various energy production and storage systems, includes a hydrogen storage system, a modeling of the hydrogen-based microgrid was developed. The model was used to analyze the expected performance of the microgrid considering different load profiles and equipment sizes. Finally, the microgrid cost-effectiveness was evaluated using a preliminary economic analysis. The results demonstrate that an effective design can be achieved with a PV system sized for an annual energy production 20% higher than the annual energy requested by the user and a hydrogen generator size 60% of the PV nominal power size. This configuration leads to a self-sufficiency rate of about 80% and, without public grants, a levelized cost of energy comparable with the cost of electricity in Italy can be achieved with a reduction of at least 25–40% of the current initial costs charged for the whole plant, depending on the load profile shape.

Optimal integration of hydrogen-based energy storage systems in photovoltaic microgrids: a techno-economic assessment

Petrollese M.;Cau G.
2020-01-01

Abstract

The feasibility and cost-effectiveness of hydrogen-based microgrids in facilities, such as public buildings and small- and medium-sized enterprises, provided by photovoltaic (PV) plants and characterized by low electric demand during weekends, were investigated in this paper. Starting from the experience of the microgrid being built at the Renewable Energy Facility of Sardegna Ricerche (Italy), which, among various energy production and storage systems, includes a hydrogen storage system, a modeling of the hydrogen-based microgrid was developed. The model was used to analyze the expected performance of the microgrid considering different load profiles and equipment sizes. Finally, the microgrid cost-effectiveness was evaluated using a preliminary economic analysis. The results demonstrate that an effective design can be achieved with a PV system sized for an annual energy production 20% higher than the annual energy requested by the user and a hydrogen generator size 60% of the PV nominal power size. This configuration leads to a self-sufficiency rate of about 80% and, without public grants, a levelized cost of energy comparable with the cost of electricity in Italy can be achieved with a reduction of at least 25–40% of the current initial costs charged for the whole plant, depending on the load profile shape.
2020
hydrogen-based microgrid; energy storage system; hydrogen-based energy storage plant
File in questo prodotto:
File Dimensione Formato  
energies-13-04149.pdf

accesso aperto

Descrizione: articolo online
Tipologia: versione editoriale
Dimensione 6.68 MB
Formato Adobe PDF
6.68 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/299713
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 10
social impact