Small-intestine contrast ultrasonography (SICUS) is a radiation-free technique that can detect intestinal damage in patients with Crohn's disease (CD). We evaluated the diagnostic accuracy of SICUS in determining the site, extent, and complications of CD, compared with computed tomography (CT) enteroclysis as the standard. We performed a retrospective analysis of data from 59 patients with CD evaluated by SICUS and CT enteroclysis 3 months apart, between January 2007 and April 2012. We evaluated disease site (based on bowel wall thickness), extent of lesions, and presence of complications (stenosis, prestenotic dilation, abscess, or fistulas) using CT enteroclysis as the standard. Sensitivity, specificity, and diagnostic accuracy were calculated. We determined the correlations in maximum wall thickness and disease extent in the small bowel between results from SICUS and CT enteroclysis. SICUS identified the site of small bowel CD with 98% sensitivity, 67% specificity, and 95% diagnostic accuracy; it identified the site of colon CD with 83% sensitivity, 97.5% specificity, and 93% diagnostic accuracy. Results from SICUS and CT enteroclysis correlated in determination of bowel wall thickness (rho, 0.79) and disease extent (rho, 0.89; P< .0001 for both). SICUS detected ileal stenosis with 95.5% sensitivity, 80% specificity, and 91.5% diagnostic accuracy, and prestenotic dilation with 87% sensitivity, 67% specificity, and 75% diagnostic accuracy. SICUS detected abscesses with 78% sensitivity, 100% specificity, and 97% diagnostic accuracy, and fistulas with 78.5% sensitivity, 95.5% specificity, and 91.5% diagnostic accuracy. SICUS identified lesions and complications in patients with CD with high levels of sensitivity, specificity, and accuracy compared with CT enteroclysis. SICUS might be used as an imaging tool as part of a focused diagnostic examination of patients with CD.

Accuracy of small-intestine contrast ultrasonography, compared with computed tomography enteroclysis, in characterizing lesions in patients with Crohn's disease

Onali S.;
2013-01-01

Abstract

Small-intestine contrast ultrasonography (SICUS) is a radiation-free technique that can detect intestinal damage in patients with Crohn's disease (CD). We evaluated the diagnostic accuracy of SICUS in determining the site, extent, and complications of CD, compared with computed tomography (CT) enteroclysis as the standard. We performed a retrospective analysis of data from 59 patients with CD evaluated by SICUS and CT enteroclysis 3 months apart, between January 2007 and April 2012. We evaluated disease site (based on bowel wall thickness), extent of lesions, and presence of complications (stenosis, prestenotic dilation, abscess, or fistulas) using CT enteroclysis as the standard. Sensitivity, specificity, and diagnostic accuracy were calculated. We determined the correlations in maximum wall thickness and disease extent in the small bowel between results from SICUS and CT enteroclysis. SICUS identified the site of small bowel CD with 98% sensitivity, 67% specificity, and 95% diagnostic accuracy; it identified the site of colon CD with 83% sensitivity, 97.5% specificity, and 93% diagnostic accuracy. Results from SICUS and CT enteroclysis correlated in determination of bowel wall thickness (rho, 0.79) and disease extent (rho, 0.89; P< .0001 for both). SICUS detected ileal stenosis with 95.5% sensitivity, 80% specificity, and 91.5% diagnostic accuracy, and prestenotic dilation with 87% sensitivity, 67% specificity, and 75% diagnostic accuracy. SICUS detected abscesses with 78% sensitivity, 100% specificity, and 97% diagnostic accuracy, and fistulas with 78.5% sensitivity, 95.5% specificity, and 91.5% diagnostic accuracy. SICUS identified lesions and complications in patients with CD with high levels of sensitivity, specificity, and accuracy compared with CT enteroclysis. SICUS might be used as an imaging tool as part of a focused diagnostic examination of patients with CD.
2013
CD; CT; Crohn's disease; cross-sectional imaging technique; detection; IBD; inflammatory bowel disease; NPV; PEG; PPV; SICUS; US; computed tomography; negative predictive value; polyethylene glycol; positive predictive value; small-intestine contrast ultrasonography; ultrasound; adult; aged; Crohn disease; female; humans; intestine small; male; middle aged; retrospective studies; sensitivity and specificity; tomography x-ray computed; ultrasonography; young adult
File in questo prodotto:
File Dimensione Formato  
calabrese et al clin gastro hepatol 2013.pdf

Solo gestori archivio

Dimensione 1.9 MB
Formato Adobe PDF
1.9 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/301752
Citazioni
  • ???jsp.display-item.citation.pmc??? 14
  • Scopus 51
  • ???jsp.display-item.citation.isi??? 45
social impact