Background: Septate uterus is a common Mullerian ducts anomaly. The aim of our pilot study was the evaluation of diode laser hysteroscopic metroplasty efficacy to increase endometrial volume in women with septate uterus. Results: We prospectively enrolled 10 consecutive patients with septate uterus undergoing office hysteroscopic metroplasty with diode laser between February and November 2019. Endometrial volume was evaluated before and 3 months after surgery using 3D transvaginal ultrasound. The surgical procedure was uncomplicated in all patients, the endometrial volume increased at 3 months follow-up (the median increase was 1.9 cm3 (range 1.7– 2.1), and there was a complete removal of septum with no intrauterine synechiae at follow-up hysteroscopy. Conclusions: Office hysteroscopic metroplasty with diode laser is a safe procedure and has preliminary showed to increase endometrial volume. The increase in endometrial volume by 3D-TV US could be used as a prognostic factor for the reproductive outcomes.
The use of hysteroscopic metroplasty with diode laser to increase endometrial volume in women with septate uterus: preliminary results
Angioni, Stefano;
2021-01-01
Abstract
Background: Septate uterus is a common Mullerian ducts anomaly. The aim of our pilot study was the evaluation of diode laser hysteroscopic metroplasty efficacy to increase endometrial volume in women with septate uterus. Results: We prospectively enrolled 10 consecutive patients with septate uterus undergoing office hysteroscopic metroplasty with diode laser between February and November 2019. Endometrial volume was evaluated before and 3 months after surgery using 3D transvaginal ultrasound. The surgical procedure was uncomplicated in all patients, the endometrial volume increased at 3 months follow-up (the median increase was 1.9 cm3 (range 1.7– 2.1), and there was a complete removal of septum with no intrauterine synechiae at follow-up hysteroscopy. Conclusions: Office hysteroscopic metroplasty with diode laser is a safe procedure and has preliminary showed to increase endometrial volume. The increase in endometrial volume by 3D-TV US could be used as a prognostic factor for the reproductive outcomes.File | Dimensione | Formato | |
---|---|---|---|
Nappi Gyn Surg 2021.pdf
accesso aperto
Tipologia:
versione editoriale (VoR)
Dimensione
5.16 MB
Formato
Adobe PDF
|
5.16 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.