Study Objectives: In heart failure (HF), we observed two patterns of hyperpnea during Cheyne-Stokes respiration with central sleep apnea (CSR-CSA): a positive pattern where end-expiratory lung volume remains at or above functional residual capacity, and a negative pattern where it falls below functional residual capacity. We hypothesized the negative pattern is associated with worse HF. Methods: Patients with HF underwent polysomnography. During CSR-CSA, hyperpnea, apnea-hyperpnea cycle, and lung to finger circulation times (LFCT) were measured. Plasma N-terminal prohormone of brain natriuretic peptide (NT-proBNP) concentration and left ventricular ejection fraction (LVEF) were assessed. Results: Of 33 patients with CSR-CSA (31 men, mean age 68 years), 9 had a negative hyperpnea pattern. There was no difference in age, body mass index, and apnea-hypopnea index between groups. Patients with a negative pattern had longer hyperpnea time (39.5 ± 6.4 versus 25.8 ± 5.9 seconds, P < .01), longer cycle time (67.8 ± 15.9 versus 51.7 ± 9.9 seconds, P < .01), higher NT-proBNP concentrations (2740 [6769] versus 570 [864] pg/ml, P = .01), and worse New York Heart Association class (P = .02) than those with a positive pattern. LFCT and LVEF did not differ between groups. Conclusions: Patients with HF and a negative CSR-CSA pattern have evidence of worse cardiac function than those with a positive pattern. Greater positive expiratory pressure during hyperpnea is likely generated during the negative pattern and might support stroke volume in patients with worse cardiac function.
Distinct Patterns of Hyperpnea During Cheyne-Stokes Respiration: Implication for Cardiac Function in Patients With Heart Failure
Redolfi S;
2017-01-01
Abstract
Study Objectives: In heart failure (HF), we observed two patterns of hyperpnea during Cheyne-Stokes respiration with central sleep apnea (CSR-CSA): a positive pattern where end-expiratory lung volume remains at or above functional residual capacity, and a negative pattern where it falls below functional residual capacity. We hypothesized the negative pattern is associated with worse HF. Methods: Patients with HF underwent polysomnography. During CSR-CSA, hyperpnea, apnea-hyperpnea cycle, and lung to finger circulation times (LFCT) were measured. Plasma N-terminal prohormone of brain natriuretic peptide (NT-proBNP) concentration and left ventricular ejection fraction (LVEF) were assessed. Results: Of 33 patients with CSR-CSA (31 men, mean age 68 years), 9 had a negative hyperpnea pattern. There was no difference in age, body mass index, and apnea-hypopnea index between groups. Patients with a negative pattern had longer hyperpnea time (39.5 ± 6.4 versus 25.8 ± 5.9 seconds, P < .01), longer cycle time (67.8 ± 15.9 versus 51.7 ± 9.9 seconds, P < .01), higher NT-proBNP concentrations (2740 [6769] versus 570 [864] pg/ml, P = .01), and worse New York Heart Association class (P = .02) than those with a positive pattern. LFCT and LVEF did not differ between groups. Conclusions: Patients with HF and a negative CSR-CSA pattern have evidence of worse cardiac function than those with a positive pattern. Greater positive expiratory pressure during hyperpnea is likely generated during the negative pattern and might support stroke volume in patients with worse cardiac function.File | Dimensione | Formato | |
---|---|---|---|
26.pdf
Solo gestori archivio
Tipologia:
versione editoriale (VoR)
Dimensione
1.56 MB
Formato
Adobe PDF
|
1.56 MB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.