BACKGROUND/AIMS: Liver biopsy has always represented the standard of reference in hepatic fibrosis assessment. Recently, blood markers and instrumental methods have been proposed for non-invasive assessment. The aim of this study was to validate transient elastography and other non-invasive tests compared to liver histology in Wilson's Disease. METHODS: Liver stiffness in 35 Wilson's Disease patients was evaluated by Fibroscan, serum fibrosis markers (AST-to-platelet-ratio index and FIB-4) and biopsy. RESULTS: Compared to liver histology, the FibroScan values increased proportionally with progression of the histological fibrosis stage. Significant fibrosis could be predicted with a Fibroscan cut-off value of 6.6 kPa. Advanced fibrosis could be predicted with a FibroScan cut-off value of 8.4 kPa. Serum fibrosis marker values gave good correlation with hepatic stage. CONCLUSIONS: A FibroScan value of 6.6 kPa was found to be a significant separation limit for differentiating significant fibrosis stages from milder stages and a fibroscan value of 8.4 kPa was found to be a significant separation limit for differentiating advanced fibrosis stages from milder stages. FibroScan values are clinically useful for predicting fibrosis stages and helpful in managing chronic therapy in Wilson's Disease patients.
Non-invasive assessment of hepatic fibrosis in a series of patients with Wilson's Disease
DEMELIA, LUIGI
2012-01-01
Abstract
BACKGROUND/AIMS: Liver biopsy has always represented the standard of reference in hepatic fibrosis assessment. Recently, blood markers and instrumental methods have been proposed for non-invasive assessment. The aim of this study was to validate transient elastography and other non-invasive tests compared to liver histology in Wilson's Disease. METHODS: Liver stiffness in 35 Wilson's Disease patients was evaluated by Fibroscan, serum fibrosis markers (AST-to-platelet-ratio index and FIB-4) and biopsy. RESULTS: Compared to liver histology, the FibroScan values increased proportionally with progression of the histological fibrosis stage. Significant fibrosis could be predicted with a Fibroscan cut-off value of 6.6 kPa. Advanced fibrosis could be predicted with a FibroScan cut-off value of 8.4 kPa. Serum fibrosis marker values gave good correlation with hepatic stage. CONCLUSIONS: A FibroScan value of 6.6 kPa was found to be a significant separation limit for differentiating significant fibrosis stages from milder stages and a fibroscan value of 8.4 kPa was found to be a significant separation limit for differentiating advanced fibrosis stages from milder stages. FibroScan values are clinically useful for predicting fibrosis stages and helpful in managing chronic therapy in Wilson's Disease patients.File | Dimensione | Formato | |
---|---|---|---|
2012..Sini..Non invasive...pdf
Solo gestori archivio
Tipologia:
versione editoriale (VoR)
Dimensione
270.02 kB
Formato
Adobe PDF
|
270.02 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.