Context: Myocardial injury during cardiac surgery on cardiopulmonary bypass (CPB) is a major determinant of morbidity and mortality. Preclinical and clinical evidence of dose- and time-related cardioprotective effects of volatile anesthetic drugs exist and their use during the whole surgery duration could improve perioperative cardiac protection. Even if administering volatile agents during CPB are relatively easy, technical problems, such as waste gas scavenging, may prevent safe and manageable administration of halogenated vapors during CPB. Aims: The aim of this study is to improve the safe administration of volatile anesthesia during CPB. Settings and Design: Tertiary teaching hospital. Subjects and Methods: We describe an original device that collects and disposes of any volatile anesthetic vapors present in the exit stream of the oxygenator, hence preventing its dispersal into the operating theatre environment and adaptively regulates pressure of oxygenator chamber in the CPB circuit. Results: We have so far applied a prototype of this device in more than 1300 adult cardiac surgery patients who received volatile anesthetics during the CPB phase. Conclusions: Widespread implementation of scavenging system like the one we designed may facilitate the perfusionist and the anesthesiologist in delivering these cardioprotective drugs with beneficial impact on patients' outcome without compromising on safety.

An innovative technique to improve safety of volatile anesthetics suction from the cardiopulmonary bypass circuit

Sardo S.
Writing – Original Draft Preparation
;
2017-01-01

Abstract

Context: Myocardial injury during cardiac surgery on cardiopulmonary bypass (CPB) is a major determinant of morbidity and mortality. Preclinical and clinical evidence of dose- and time-related cardioprotective effects of volatile anesthetic drugs exist and their use during the whole surgery duration could improve perioperative cardiac protection. Even if administering volatile agents during CPB are relatively easy, technical problems, such as waste gas scavenging, may prevent safe and manageable administration of halogenated vapors during CPB. Aims: The aim of this study is to improve the safe administration of volatile anesthesia during CPB. Settings and Design: Tertiary teaching hospital. Subjects and Methods: We describe an original device that collects and disposes of any volatile anesthetic vapors present in the exit stream of the oxygenator, hence preventing its dispersal into the operating theatre environment and adaptively regulates pressure of oxygenator chamber in the CPB circuit. Results: We have so far applied a prototype of this device in more than 1300 adult cardiac surgery patients who received volatile anesthetics during the CPB phase. Conclusions: Widespread implementation of scavenging system like the one we designed may facilitate the perfusionist and the anesthesiologist in delivering these cardioprotective drugs with beneficial impact on patients' outcome without compromising on safety.
2017
Anesthesia
cardiac surgery
cardiopulmonary bypass
sevoflurane
volatile
Adult
Anesthesia, Inhalation
Anesthesiology
Anesthetics, Inhalation
Cardiac Surgical Procedures
Cardiopulmonary Bypass
Cardiotonic Agents
Equipment Design
Extracorporeal Circulation
Hospitals, Teaching
Humans
Oxygenators, Membrane
Safety
Suction
Tertiary Care Centers
Gas Scavengers
File in questo prodotto:
File Dimensione Formato  
An Innovative Technique to Improve Safety of Volatile Anesthetics Suction from the Cardiopulmonary Bypass Circuit.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: versione editoriale
Dimensione 1.08 MB
Formato Adobe PDF
1.08 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/329026
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 4
social impact