Purpose: To investigate the behavior of silicone oil (SiO) at a steady equilibrium and during saccades in pseudophakic highly myopic eyes with posterior staphyloma with and without an encircling band and compare it to behavior in emmetropic eyes. The SiO-retina contact area and shear stress were calculated by computational fluid dynamics. Methods: A numerical model of an emmetropic eye and a myopic eye with and without scleral band underwent a saccade of 50 degrees/0.137 s. The vitreous chamber surface was divided into superior and inferior 180 degrees sectors: lens, pre-equator, post-equator, and macula. SiO-retina contact was evaluated as a function of fill percentages between 80% and 90% for standing, 45 degrees upward tilt, and supine patients. Maximum and average shear stress were calculated. Results: Overall, SiO-retina contact ranged between 40% and 83%; fill percentage varied between 80% and 95%. Neither the encircling scleral band nor the staphyloma significantly affected the SiO-retina contact area, although the presence of a scleral band proved disadvantageous when gazing 45 degrees upward. The inferior retina-SiO contact remained below 40% despite 95% SiO fill. The SS significantly increased at the scleral band indentation and decreased elsewhere. The staphyloma greatly reduced shear stress at the macula. Conclusions: The presence of a myopic staphyloma reduces shear stress at the macula but does not alter SiO-retina contact significantly. The apposition of a 360 degrees scleral band may reduce SiO-retina contact at least in some postures and increases the SS at the indentation. Translational Relevance: Assessing SiO-retina contact when vitreous chamber geometry changes according to pathologic or iatrogenic modifications allows accurate prediction of real-life tamponade behavior and helps explain surgical outcomes.

Silicone Oil Tamponade-Retina Contact in Highly Myopic Eyes With and Without Encircling Bands: A Computational Fluid Dynamics Study

Querzoli, Giorgio
Secondo
;
Badas, Maria Grazia;Angius, Federico;
2022-01-01

Abstract

Purpose: To investigate the behavior of silicone oil (SiO) at a steady equilibrium and during saccades in pseudophakic highly myopic eyes with posterior staphyloma with and without an encircling band and compare it to behavior in emmetropic eyes. The SiO-retina contact area and shear stress were calculated by computational fluid dynamics. Methods: A numerical model of an emmetropic eye and a myopic eye with and without scleral band underwent a saccade of 50 degrees/0.137 s. The vitreous chamber surface was divided into superior and inferior 180 degrees sectors: lens, pre-equator, post-equator, and macula. SiO-retina contact was evaluated as a function of fill percentages between 80% and 90% for standing, 45 degrees upward tilt, and supine patients. Maximum and average shear stress were calculated. Results: Overall, SiO-retina contact ranged between 40% and 83%; fill percentage varied between 80% and 95%. Neither the encircling scleral band nor the staphyloma significantly affected the SiO-retina contact area, although the presence of a scleral band proved disadvantageous when gazing 45 degrees upward. The inferior retina-SiO contact remained below 40% despite 95% SiO fill. The SS significantly increased at the scleral band indentation and decreased elsewhere. The staphyloma greatly reduced shear stress at the macula. Conclusions: The presence of a myopic staphyloma reduces shear stress at the macula but does not alter SiO-retina contact significantly. The apposition of a 360 degrees scleral band may reduce SiO-retina contact at least in some postures and increases the SS at the indentation. Translational Relevance: Assessing SiO-retina contact when vitreous chamber geometry changes according to pathologic or iatrogenic modifications allows accurate prediction of real-life tamponade behavior and helps explain surgical outcomes.
2022
Pars plana vitrectomy; high myopia; posterior staphyloma; encircling band; computational model; computational fluid dynamics; silicone oil tamponade; shear stress; silicone oil; Humans; Silicone Oils; Myopia; Retinal Detachment; Scleral Diseases
File in questo prodotto:
File Dimensione Formato  
Rossi et al. - 2022 - Silicone Oil Tamponade–Retina Contact in Highly My.pdf

accesso aperto

Tipologia: versione editoriale
Dimensione 2.55 MB
Formato Adobe PDF
2.55 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/340595
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 3
social impact