Post-tensioning structures with metallic ducts risk corrosion, rupture or collapses due to chloride ingress. The use of tight corrugated polymer ducts combined with electrically isolated anchorag-es (EIT) changed the situation. Laboratory and many field applications proved the tightness of the duct, showing resistance values higher or much higher than 50 kΩm, the acceptance criteria for a tight duct. The most important fact is that EIT tendons allow quality control and long-term mon-itoring of the duct tightness. EIT ducts (also with resistance values below the threshold criteria) can be monitored over the whole service life: only a progressive decrease of the measured re-sistance indicates a corrosion risk for this specific tendon. The most important structural elements can be easily monitored for the first time and damage initiation can be detected early. After a successful use in Europe EIT technology is now expanding progressively in the US.

Prevention of corrosion in post-tensioned structures: electrically isolated tendons

Elsener Bernhard
2022-01-01

Abstract

Post-tensioning structures with metallic ducts risk corrosion, rupture or collapses due to chloride ingress. The use of tight corrugated polymer ducts combined with electrically isolated anchorag-es (EIT) changed the situation. Laboratory and many field applications proved the tightness of the duct, showing resistance values higher or much higher than 50 kΩm, the acceptance criteria for a tight duct. The most important fact is that EIT tendons allow quality control and long-term mon-itoring of the duct tightness. EIT ducts (also with resistance values below the threshold criteria) can be monitored over the whole service life: only a progressive decrease of the measured re-sistance indicates a corrosion risk for this specific tendon. The most important structural elements can be easily monitored for the first time and damage initiation can be detected early. After a successful use in Europe EIT technology is now expanding progressively in the US.
2022
Durability; Non-destructive testing; Polymer ducts; Electrically isolated tendons; Long-term monitoring
File in questo prodotto:
File Dimensione Formato  
cmd-03-00024.pdf

accesso aperto

Tipologia: versione editoriale
Dimensione 1.75 MB
Formato Adobe PDF
1.75 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/341856
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? ND
social impact