In order to move forward in the acceptance of a novel contaminant monitoring technique (Diffusive Gradients in Thin-films: DGT) for assessment of marine water bodies, sensu the WFD, an Inter-Laboratories Comparison (ILC) exercise (nine Europeans laboratories) was organized in the framework of the Interreg Atlantic Area MONITOOL project, which focused on the use of the DGT technique for the measurement of WFD priority metals (Cd, Ni and Pb). Reproducible results were obtained for each metal by several laboratories, supporting the assertion that DGT analysis can be performed satisfactorily by laboratories experienced in measuring metals at trace levels in marine environments, even if they have limited practice in DGT analysis. According to the Z-score analysis, among the 9 participating laboratories, 3 had 100 % of satisfactory results for Cd, Ni, and Pb, 3 had >80 % satisfactory results and 2 had about 60 % satisfactory results. This work highlights the need to clearly describe the DGT method in order to control sources of contamination during analytical steps, in particular the resin gel retrieval and the elution steps. Such international intercomparison exercise is an important step to develop the laboratory network involved in DGT analysis and contributes to the improvement of data quality.

An international intercomparison exercise on passive samplers (DGT) for monitoring metals in marine waters under a regulatory context

Marras B.;Schintu M.;Belzunce-Segarra M. J.;
2022-01-01

Abstract

In order to move forward in the acceptance of a novel contaminant monitoring technique (Diffusive Gradients in Thin-films: DGT) for assessment of marine water bodies, sensu the WFD, an Inter-Laboratories Comparison (ILC) exercise (nine Europeans laboratories) was organized in the framework of the Interreg Atlantic Area MONITOOL project, which focused on the use of the DGT technique for the measurement of WFD priority metals (Cd, Ni and Pb). Reproducible results were obtained for each metal by several laboratories, supporting the assertion that DGT analysis can be performed satisfactorily by laboratories experienced in measuring metals at trace levels in marine environments, even if they have limited practice in DGT analysis. According to the Z-score analysis, among the 9 participating laboratories, 3 had 100 % of satisfactory results for Cd, Ni, and Pb, 3 had >80 % satisfactory results and 2 had about 60 % satisfactory results. This work highlights the need to clearly describe the DGT method in order to control sources of contamination during analytical steps, in particular the resin gel retrieval and the elution steps. Such international intercomparison exercise is an important step to develop the laboratory network involved in DGT analysis and contributes to the improvement of data quality.
2022
Interlaboratory exercise; Water framework directive; Passive sampling; DGT; Priority metals
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/345494
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact