We show that adding CF4 to the standard Ar/CO2 gas mixture allows to substantially improve the time resolution of triple-GEM detectors. In this paper we discuss measurements of time resolution, discharge probability per incident charged particle and pad multiplicity of a triple-GEM detector with pad readout, with new gas mixtures with CF4 and isobutane. Results for detectors with GEM foil size of both 10 x 10 cm(2) and 20 x 24 cm(2) are presented. (C) 2004 Published by Elsevier B.V.

A triple-GEM detector for high-rate particle triggering

Bonivento W;SAITTA, BIAGIO
2004-01-01

Abstract

We show that adding CF4 to the standard Ar/CO2 gas mixture allows to substantially improve the time resolution of triple-GEM detectors. In this paper we discuss measurements of time resolution, discharge probability per incident charged particle and pad multiplicity of a triple-GEM detector with pad readout, with new gas mixtures with CF4 and isobutane. Results for detectors with GEM foil size of both 10 x 10 cm(2) and 20 x 24 cm(2) are presented. (C) 2004 Published by Elsevier B.V.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.