Triple-GEM detectors with pad readout has been tested at the CERN PS T11 Hadron Beam Facility. A time distribution RMS of 6 ns has been obtained with an Ar/CO2/CF4 (60/20/20) gas mixture, achieving a substantial improvement with respect to Ar/CO2 (70/30), where an RMS of 10 ns was obtained. This resulted in an efficiency of about 96% in a 25 ns time-window (and a total efficiency of 99.7%), suggesting that these detectors could be interesting devices for triggering at the typical LHC interaction rate. (C) 2002 Elsevier Science B.V. All rights reserved.
A fast triple-GEM detector for high-rate charged-particle triggering RID A-6640-2010
Bonivento W;SAITTA, BIAGIO;
2002-01-01
Abstract
Triple-GEM detectors with pad readout has been tested at the CERN PS T11 Hadron Beam Facility. A time distribution RMS of 6 ns has been obtained with an Ar/CO2/CF4 (60/20/20) gas mixture, achieving a substantial improvement with respect to Ar/CO2 (70/30), where an RMS of 10 ns was obtained. This resulted in an efficiency of about 96% in a 25 ns time-window (and a total efficiency of 99.7%), suggesting that these detectors could be interesting devices for triggering at the typical LHC interaction rate. (C) 2002 Elsevier Science B.V. All rights reserved.I metadati presenti in IRIS UNICA sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono protetti da diritto d'autore, salvo diversa indicazione.