Background-Subendocardial thickening is greater than subepicardial thickening and acute myocardial ischemia mainly impairs the former. Integrated backscatter cyclic variations (IBScv) reflect regional myocardial contractility and are blunted during myocardial ischemia. We hypothesized that stress-induced myocardial ischemia mainly affects subendocardial IBScv. Methods and Results-Multiplane transesophageal echocardiography and simultaneous atrial pacing were performed in 12 patients without coronary artery disease (CAD) and in 25 with significant CAD. In a transgastric 2-chamber view, we calculated IBScv in subendocardium and subepicardium and a heterogeneity index, both at rest and at peak-pacing. In 27 myocardial segments of patients with normal coronary arteries, and in 16 myocardial segments supplied by coronary artery without significant stenosis in patients with CAD, there was a transmural gradient of IBScv at rest and the heterogeneity index did not change during all the protocol steps. In the 53 myocardial segments related to a significantly narrowed coronary artery, the transmural gradient of IBScv, present at rest, significantly decreased at peak-pacing because of subendocardial blunting, but promptly recovered 5 seconds after pacing interruption. Moreover, the myocardial thickening at rest and peak pacing correlated with the subendocardial IBScv behavior and not with the subepicardial one. Conclusions-IBScv are greater in the subendocardium than in the subepicardium. Atrial pacing stress test does not affect IBScv in segments supplied by nonstenotic coronary arteries, whereas it affects segments supplied by diseased coronary arteries, blunting exclusively subendocardial IBScv. Heterogeneity of IBScv intramyocardial changes caused by stress-induced ischemia must be taken into account when using IBScv for investigating myocardial ischemia.

Effects of acute myocardial ischemia on intramyocardial contraction heterogeneity: A study performed with ultrasound integrated backscatter during transesophageal atrial pacing

MONTISCI, ROBERTA;MELONI, LUIGI;
1999-01-01

Abstract

Background-Subendocardial thickening is greater than subepicardial thickening and acute myocardial ischemia mainly impairs the former. Integrated backscatter cyclic variations (IBScv) reflect regional myocardial contractility and are blunted during myocardial ischemia. We hypothesized that stress-induced myocardial ischemia mainly affects subendocardial IBScv. Methods and Results-Multiplane transesophageal echocardiography and simultaneous atrial pacing were performed in 12 patients without coronary artery disease (CAD) and in 25 with significant CAD. In a transgastric 2-chamber view, we calculated IBScv in subendocardium and subepicardium and a heterogeneity index, both at rest and at peak-pacing. In 27 myocardial segments of patients with normal coronary arteries, and in 16 myocardial segments supplied by coronary artery without significant stenosis in patients with CAD, there was a transmural gradient of IBScv at rest and the heterogeneity index did not change during all the protocol steps. In the 53 myocardial segments related to a significantly narrowed coronary artery, the transmural gradient of IBScv, present at rest, significantly decreased at peak-pacing because of subendocardial blunting, but promptly recovered 5 seconds after pacing interruption. Moreover, the myocardial thickening at rest and peak pacing correlated with the subendocardial IBScv behavior and not with the subepicardial one. Conclusions-IBScv are greater in the subendocardium than in the subepicardium. Atrial pacing stress test does not affect IBScv in segments supplied by nonstenotic coronary arteries, whereas it affects segments supplied by diseased coronary arteries, blunting exclusively subendocardial IBScv. Heterogeneity of IBScv intramyocardial changes caused by stress-induced ischemia must be taken into account when using IBScv for investigating myocardial ischemia.
1999
coronary disease; echocardiography; pacing; ischemia; myocardial contraction
File in questo prodotto:
File Dimensione Formato  
COlonna_Circulation 1999.pdf

accesso aperto

Tipologia: versione post-print
Dimensione 372.61 kB
Formato Adobe PDF
372.61 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/376
Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 23
social impact