In this study, a fully-featured electrochemiluminescence (ECL) sensing platform based on a multichannel closed bipolar system (closed-BP, C-BP) for the determination of caffeic acid (CA) was successfully developed. The system comprises three individual reservoirs connected to each other by two pairs of gold rods as bipolar electrodes. Moreover, a single pair of gold rods functions as the driving electrodes. Due to configuration consisting of three channels and double-bipolar electrodes, the detection of CA was accomplished in two oxidation and reduction pathways within a single device. Firstly, through close observation of the reactions occurring within the device and utilizing a universal pH indicator and bipolar electrodes, a precise mechanism for the current bipolar systems was initially proposed. Then, the concentration of CA was monitored in the reporting chamber through the following ECL intensities resulting from luminol oxidation and H2O2. The monitoring process was performed using both a photomultiplier tube (PMT) and a digital camera. In the process of analyte oxidation, the PMT and visual (camera)-based detection exhibited a linear response from 5 μmol L−1 to 700 μmol L−1 (limit of detection (LOD) 1.2 μmol L−1) and 50 μmol L−1 to 600 μmol L−1 (LOD 14.8 μmol L−1), respectively. In the analyte reduction pathway, the respective values were 30 μmol L−1 to 450 μmol L−1 (LOD 8.6 μmol L−1) and 55 μmol L−1 to 400 μmol L−1 (LOD 21.2 μmol L−1), for the PMT and visual-based detection, respectively. Our experiments have demonstrated the practical application of the sensor array for efficient and high-performance analysis. This innovative design holds significant potential for diverse fields and paves the way for the development of a user-friendly device.

A multichannel closed bipolar platform to visual electrochemiluminescence sensing of caffeic acid as a model: Potential for multiplex detection

Salis A.
Ultimo
2024-01-01

Abstract

In this study, a fully-featured electrochemiluminescence (ECL) sensing platform based on a multichannel closed bipolar system (closed-BP, C-BP) for the determination of caffeic acid (CA) was successfully developed. The system comprises three individual reservoirs connected to each other by two pairs of gold rods as bipolar electrodes. Moreover, a single pair of gold rods functions as the driving electrodes. Due to configuration consisting of three channels and double-bipolar electrodes, the detection of CA was accomplished in two oxidation and reduction pathways within a single device. Firstly, through close observation of the reactions occurring within the device and utilizing a universal pH indicator and bipolar electrodes, a precise mechanism for the current bipolar systems was initially proposed. Then, the concentration of CA was monitored in the reporting chamber through the following ECL intensities resulting from luminol oxidation and H2O2. The monitoring process was performed using both a photomultiplier tube (PMT) and a digital camera. In the process of analyte oxidation, the PMT and visual (camera)-based detection exhibited a linear response from 5 μmol L−1 to 700 μmol L−1 (limit of detection (LOD) 1.2 μmol L−1) and 50 μmol L−1 to 600 μmol L−1 (LOD 14.8 μmol L−1), respectively. In the analyte reduction pathway, the respective values were 30 μmol L−1 to 450 μmol L−1 (LOD 8.6 μmol L−1) and 55 μmol L−1 to 400 μmol L−1 (LOD 21.2 μmol L−1), for the PMT and visual-based detection, respectively. Our experiments have demonstrated the practical application of the sensor array for efficient and high-performance analysis. This innovative design holds significant potential for diverse fields and paves the way for the development of a user-friendly device.
File in questo prodotto:
File Dimensione Formato  
2024 ACA 1-s2.0-S0003267023013089-main.pdf

Solo gestori archivio

Tipologia: versione editoriale (VoR)
Dimensione 5.83 MB
Formato Adobe PDF
5.83 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
ACA 2024 Pre Print.pdf

accesso aperto

Tipologia: versione pre-print
Dimensione 2.13 MB
Formato Adobe PDF
2.13 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/385826
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact