Background: Twiddler syndrome (TS) is a complication of cardiac implantable electronic device (CIED) implantation, caused by the deliberate or unconscious manipulation of the device by the patient himself, which results in dislocation of the leads by retraction towards the subcutaneous pocket. Case summary: This report describes two clinical cases that occurred in our centre, for which two different solutions were successfully implemented. In the first case, a complete removal of the stimulation system was performed, and a leadless pacemaker (PM; Medtronic Micra VR) was implanted. In the second case, the patient underwent a revision procedure. The PM was disconnected, and the electrodes were debrided, a submuscular pocket for the PM was created, and at the end of the procedure, the PM was anchored to the pectoralis major. Discussion: Twiddler syndrome is a not so rare and serious complication of CIED implantation, leading to device malfunctioning and higher risk of infection of the pocket due to multiple re-interventions. In these two cases, different surgical solutions were performed, both resulting to be effective to solve the effects of TS.

A case series of the twiddler syndrome

Montisci, Roberta
Primo
Writing – Original Draft Preparation
;
2024-01-01

Abstract

Background: Twiddler syndrome (TS) is a complication of cardiac implantable electronic device (CIED) implantation, caused by the deliberate or unconscious manipulation of the device by the patient himself, which results in dislocation of the leads by retraction towards the subcutaneous pocket. Case summary: This report describes two clinical cases that occurred in our centre, for which two different solutions were successfully implemented. In the first case, a complete removal of the stimulation system was performed, and a leadless pacemaker (PM; Medtronic Micra VR) was implanted. In the second case, the patient underwent a revision procedure. The PM was disconnected, and the electrodes were debrided, a submuscular pocket for the PM was created, and at the end of the procedure, the PM was anchored to the pectoralis major. Discussion: Twiddler syndrome is a not so rare and serious complication of CIED implantation, leading to device malfunctioning and higher risk of infection of the pocket due to multiple re-interventions. In these two cases, different surgical solutions were performed, both resulting to be effective to solve the effects of TS.
2024
Case series; Leadless pacemaker; Submuscular pacemaker implant; Twiddler syndrome
File in questo prodotto:
File Dimensione Formato  
Twiddler _def.pdf

accesso aperto

Tipologia: versione editoriale (VoR)
Dimensione 2.28 MB
Formato Adobe PDF
2.28 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/389203
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact