Intraoperative transesophageal echocardiography (TEE) was used to monitor the removal of intracardiac masses in 17 patients. Prebypass TEE was used to confirm the preoperative diagnosis. It gave a clear image and anatomical definition of the mass in 16 cases. Moreover, in 11 of these patients, prebypass TEE provided information not obtained previously by traditional exams. This information was judged either useful or indispensable for a successful outcome in 10 of these patients. However, in one of the remaining six patients, TEE did not clearly visualize a flat thrombus in the left atrium. Postbypass TEE was used in each case to monitor the surgical results of the mass removal and the associated procedures. In one patient, it disclosed a progressively expanding hematoma in the left atrial wall, which was interfering with mitral valve function. From this experience, we consider intraoperative TEE the best monitoring device during cardiac mass removal because it usually provides a more complete diagnosis and anatomical definition of the mass than the traditional preoperative methods and permits monitoring of the surgical results before chest closure. Some limitations to this method may exist.

The role of transesophageal echocardiography in the monitoring of cardiac mass removal: a review of 17 cases

MELONI, LUIGI;
1993-01-01

Abstract

Intraoperative transesophageal echocardiography (TEE) was used to monitor the removal of intracardiac masses in 17 patients. Prebypass TEE was used to confirm the preoperative diagnosis. It gave a clear image and anatomical definition of the mass in 16 cases. Moreover, in 11 of these patients, prebypass TEE provided information not obtained previously by traditional exams. This information was judged either useful or indispensable for a successful outcome in 10 of these patients. However, in one of the remaining six patients, TEE did not clearly visualize a flat thrombus in the left atrium. Postbypass TEE was used in each case to monitor the surgical results of the mass removal and the associated procedures. In one patient, it disclosed a progressively expanding hematoma in the left atrial wall, which was interfering with mitral valve function. From this experience, we consider intraoperative TEE the best monitoring device during cardiac mass removal because it usually provides a more complete diagnosis and anatomical definition of the mass than the traditional preoperative methods and permits monitoring of the surgical results before chest closure. Some limitations to this method may exist.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/40831
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact