Implantable medical devices present several technological challenges, one of the most critical being how to provide power supply and communication capabilities to a device hermetically sealed within the body. Using a battery as a power source represents a potential harm for the individual’s health because of possible toxic chemical release or overheating, and it requires periodic surgery for replacement. This paper proposes a batteryless implantable device powered by an inductive link and equipped with bidirectional wireless communication channels. The device, designed in a 180 nm CMOS process, is based on two different pairs of mutually coupled inductors that provide, respectively, power and a low-bitrate bidirectional communication link and a separate, high-bitrate, one-directional upstream connection. The main link is based on a 13.56 MHz carrier and allows power transmission and a half-duplex two-way communication at 106 kbps (downlink) and 30 kbps (uplink). The secondary link is based on a 27 MHz carrier, which provides one-way communication at 2.25 Mbps only in uplink. The low-bitrate links are needed to send commands and monitor the implanted system, while the high-bitrate link is required to receive a continuous stream of information from the implanted sensing devices. The microchip acts as a hub for power and data wireless transmission capable of managing up to four different neural recording and stimulation front ends, making the device employable in a complex, distributed, bidirectional neural prosthetic system.

A Bidirectional, Full-Duplex, Implantable Wireless CMOS System for Prosthetic Control

Collu, Riccardo
Investigation
;
Salis, Cinzia
Investigation
;
Ferrazzano, Elena
Writing – Review & Editing
;
Barbaro, Massimo
Supervision
2025-01-01

Abstract

Implantable medical devices present several technological challenges, one of the most critical being how to provide power supply and communication capabilities to a device hermetically sealed within the body. Using a battery as a power source represents a potential harm for the individual’s health because of possible toxic chemical release or overheating, and it requires periodic surgery for replacement. This paper proposes a batteryless implantable device powered by an inductive link and equipped with bidirectional wireless communication channels. The device, designed in a 180 nm CMOS process, is based on two different pairs of mutually coupled inductors that provide, respectively, power and a low-bitrate bidirectional communication link and a separate, high-bitrate, one-directional upstream connection. The main link is based on a 13.56 MHz carrier and allows power transmission and a half-duplex two-way communication at 106 kbps (downlink) and 30 kbps (uplink). The secondary link is based on a 27 MHz carrier, which provides one-way communication at 2.25 Mbps only in uplink. The low-bitrate links are needed to send commands and monitor the implanted system, while the high-bitrate link is required to receive a continuous stream of information from the implanted sensing devices. The microchip acts as a hub for power and data wireless transmission capable of managing up to four different neural recording and stimulation front ends, making the device employable in a complex, distributed, bidirectional neural prosthetic system.
File in questo prodotto:
File Dimensione Formato  
2025-chip-jsan-14-00092_compressed.pdf

accesso aperto

Tipologia: versione editoriale (VoR)
Dimensione 772.77 kB
Formato Adobe PDF
772.77 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/453765
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact