Implantable medical devices present several technological challenges, one of the most critical being how to provide power supply and communication capabilities to a device hermetically sealed within the body. Using a battery as a power source represents a potential harm for the individual’s health because of possible toxic chemical release or overheating, and it requires periodic surgery for replacement. This paper proposes a batteryless implantable device powered by an inductive link and equipped with bidirectional wireless communication channels. The device, designed in a 180 nm CMOS process, is based on two different pairs of mutually coupled inductors that provide, respectively, power and a low-bitrate bidirectional communication link and a separate, high-bitrate, one-directional upstream connection. The main link is based on a 13.56 MHz carrier and allows power transmission and a half-duplex two-way communication at 106 kbps (downlink) and 30 kbps (uplink). The secondary link is based on a 27 MHz carrier, which provides one-way communication at 2.25 Mbps only in uplink. The low-bitrate links are needed to send commands and monitor the implanted system, while the high-bitrate link is required to receive a continuous stream of information from the implanted sensing devices. The microchip acts as a hub for power and data wireless transmission capable of managing up to four different neural recording and stimulation front ends, making the device employable in a complex, distributed, bidirectional neural prosthetic system.
A Bidirectional, Full-Duplex, Implantable Wireless CMOS System for Prosthetic Control
Collu, Riccardo
Investigation
;Salis, CinziaInvestigation
;Ferrazzano, ElenaWriting – Review & Editing
;Barbaro, Massimo
Supervision
2025-01-01
Abstract
Implantable medical devices present several technological challenges, one of the most critical being how to provide power supply and communication capabilities to a device hermetically sealed within the body. Using a battery as a power source represents a potential harm for the individual’s health because of possible toxic chemical release or overheating, and it requires periodic surgery for replacement. This paper proposes a batteryless implantable device powered by an inductive link and equipped with bidirectional wireless communication channels. The device, designed in a 180 nm CMOS process, is based on two different pairs of mutually coupled inductors that provide, respectively, power and a low-bitrate bidirectional communication link and a separate, high-bitrate, one-directional upstream connection. The main link is based on a 13.56 MHz carrier and allows power transmission and a half-duplex two-way communication at 106 kbps (downlink) and 30 kbps (uplink). The secondary link is based on a 27 MHz carrier, which provides one-way communication at 2.25 Mbps only in uplink. The low-bitrate links are needed to send commands and monitor the implanted system, while the high-bitrate link is required to receive a continuous stream of information from the implanted sensing devices. The microchip acts as a hub for power and data wireless transmission capable of managing up to four different neural recording and stimulation front ends, making the device employable in a complex, distributed, bidirectional neural prosthetic system.| File | Dimensione | Formato | |
|---|---|---|---|
|
2025-chip-jsan-14-00092_compressed.pdf
accesso aperto
Tipologia:
versione editoriale (VoR)
Dimensione
772.77 kB
Formato
Adobe PDF
|
772.77 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.