Forensic laboratories frequently require quantification of THC in seized cannabis plantmaterial on a dry weight basis, but conventional air drying may require prolongedpreparation times, delaying forensic reporting. This paired pilot study evaluatedwhether low-power microwave drying could provide neutral THC measurementsshowing agreement with conventional oven drying while substantially reducingpreparation time. Fresh material from 20 cannabis plants was split into matchedaliquots and dried by ambient air, laboratory oven (80°C, 10 min), or microwave(70 W, 2–3 min). Samples were analyzed by GC–MS (identification) and GC–FID(quantification). The analytical endpoint was neutral THC; THCA and total potentialTHC were not determined. Mean THC percentages were 0.898% (air), 0.829%(oven), and 0.802% (microwave). Drying method effect was significant (Friedmanχ2 = 10.47, p = 0.0053; ANOVA F(2,38) = 13.19, p < 0.001). For microwave versus ovendrying, the mean difference was −0.027 percentage points (95% CI −0.057 to 0.003;p = 0.073). Bland–Altman bias was −0.027 with 95% limits of agreement from −0.152to 0.098, and ICC(A,1) was 0.975 (95% CI: 0.938–0.991). Strict equivalence within±0.05 percentage points was not established (TOST p = 0.061). Microwave dryingsubstantially shortened preparation time and produced neutral THC measurementsshowing close agreement with oven drying under the tested conditions, althoughequivalence was not established. It may be useful for rapid preliminary assessment,but prospective validation—including residual- moisture determination, temperaturemonitoring, broader cannabinoid profiling, and full analytical validation—is requiredbefore confirmatory forensic use
Rapid forensic THC determination in cannabis plant material: A proof-of-concept study of low-power microwave drying
Nioi, Matteo
Primo
;Maccioni, Alessia;
2026-01-01
Abstract
Forensic laboratories frequently require quantification of THC in seized cannabis plantmaterial on a dry weight basis, but conventional air drying may require prolongedpreparation times, delaying forensic reporting. This paired pilot study evaluatedwhether low-power microwave drying could provide neutral THC measurementsshowing agreement with conventional oven drying while substantially reducingpreparation time. Fresh material from 20 cannabis plants was split into matchedaliquots and dried by ambient air, laboratory oven (80°C, 10 min), or microwave(70 W, 2–3 min). Samples were analyzed by GC–MS (identification) and GC–FID(quantification). The analytical endpoint was neutral THC; THCA and total potentialTHC were not determined. Mean THC percentages were 0.898% (air), 0.829%(oven), and 0.802% (microwave). Drying method effect was significant (Friedmanχ2 = 10.47, p = 0.0053; ANOVA F(2,38) = 13.19, p < 0.001). For microwave versus ovendrying, the mean difference was −0.027 percentage points (95% CI −0.057 to 0.003;p = 0.073). Bland–Altman bias was −0.027 with 95% limits of agreement from −0.152to 0.098, and ICC(A,1) was 0.975 (95% CI: 0.938–0.991). Strict equivalence within±0.05 percentage points was not established (TOST p = 0.061). Microwave dryingsubstantially shortened preparation time and produced neutral THC measurementsshowing close agreement with oven drying under the tested conditions, althoughequivalence was not established. It may be useful for rapid preliminary assessment,but prospective validation—including residual- moisture determination, temperaturemonitoring, broader cannabinoid profiling, and full analytical validation—is requiredbefore confirmatory forensic useI metadati presenti in IRIS UNICA sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono protetti da diritto d'autore, salvo diversa indicazione.