The paper investigates the structural behaviour of the masonry vaults of the Speranza Chapel in Cagliari, characterized by an unusual Gothic vaulting arrangement consisting of a central ribbed cross vault flanked by two half-vaults and by a particularly slender lateral supporting wall, whose thickness is significantly smaller than that commonly observed in comparable Gothic churches. A terrestrial laser scanning (TLS) survey was carried out to develop an accurate three-dimensional geometric model of the chapel. Based on this model, lower-bound limit analyses were employed to investigate the equilibrium conditions of the vaulting system and to evaluate the horizontal thrust transmitted to the lateral walls. To assess the structural implications of this unusual configuration, the existing vault arrangement was compared with a hypothetical solution consisting of two complete adjacent ribbed cross vaults. Nonlinear finite element analyses were subsequently performed to investigate the stress distribution, deformation pattern, and cracking behaviour under gravity loading. Analytical and numerical results indicate that the existing vaulting configuration leads to a more favourable redistribution of internal forces, reducing the horizontal thrust transmitted to the perimeter walls and limiting stress concentrations with respect to the hypothetical alternative; overall supporting the equilibrium and long-term stability of the chapel.

Form and equilibrium of an unusual gothic vaulting system: the Church of Nostra Signora della Speranza in Cagliari

Marco Zucca
;
Emanuele Reccia;Fabian Orozco;Antonio Cazzani
2026-01-01

Abstract

The paper investigates the structural behaviour of the masonry vaults of the Speranza Chapel in Cagliari, characterized by an unusual Gothic vaulting arrangement consisting of a central ribbed cross vault flanked by two half-vaults and by a particularly slender lateral supporting wall, whose thickness is significantly smaller than that commonly observed in comparable Gothic churches. A terrestrial laser scanning (TLS) survey was carried out to develop an accurate three-dimensional geometric model of the chapel. Based on this model, lower-bound limit analyses were employed to investigate the equilibrium conditions of the vaulting system and to evaluate the horizontal thrust transmitted to the lateral walls. To assess the structural implications of this unusual configuration, the existing vault arrangement was compared with a hypothetical solution consisting of two complete adjacent ribbed cross vaults. Nonlinear finite element analyses were subsequently performed to investigate the stress distribution, deformation pattern, and cracking behaviour under gravity loading. Analytical and numerical results indicate that the existing vaulting configuration leads to a more favourable redistribution of internal forces, reducing the horizontal thrust transmitted to the perimeter walls and limiting stress concentrations with respect to the hypothetical alternative; overall supporting the equilibrium and long-term stability of the chapel.
2026
Historical constructions; Masonry vaults; Laser-scanner surveys; Thrust-line analysis; Non-linear analysis
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I metadati presenti in IRIS UNICA sono rilasciati con licenza Creative Commons CC0 1.0 Universal, mentre i file delle pubblicazioni sono protetti da diritto d'autore, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/497745
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
  • OpenAlex ND
social impact