We hypothesized that the role of stroke volume (SV) in the metaboreflex-induced cardiac output (CO) increase was blunted when the metaboreflex was stimulated by exercise muscle ischemia (EMI) compared with post-exercise muscle ischemia (PEMI), because during EMI heart rate (HR) increases and limits diastolic filling. Twelve healthy volunteers were recruited and their hemodynamic responses to the metaboreflex evoked by EMI, PEMI, and by a control dynamic exercise were assessed. The main finding was that the blood pressure increment was very similar in the EMI and PEMI settings. In both conditions the main mechanism used to raise blood pressure was a CO elevation. However, during the EMI test CO was increased as a result of HR elevation whereas during the PEMI test CO was increased as a result of an increase in SV. These results were explainable on the basis of the different HR behavior between the two settings, which in turn led to different diastolic time and myocardial performance.

Role of heart rate and stroke volume during muscle metaboreflex-induced cardiac output increase: differences between activation during and after exercise.

CRISAFULLI, ANTONIO;MILIA, RAFFAELE;TOCCO, FILIPPO;
2011-01-01

Abstract

We hypothesized that the role of stroke volume (SV) in the metaboreflex-induced cardiac output (CO) increase was blunted when the metaboreflex was stimulated by exercise muscle ischemia (EMI) compared with post-exercise muscle ischemia (PEMI), because during EMI heart rate (HR) increases and limits diastolic filling. Twelve healthy volunteers were recruited and their hemodynamic responses to the metaboreflex evoked by EMI, PEMI, and by a control dynamic exercise were assessed. The main finding was that the blood pressure increment was very similar in the EMI and PEMI settings. In both conditions the main mechanism used to raise blood pressure was a CO elevation. However, during the EMI test CO was increased as a result of HR elevation whereas during the PEMI test CO was increased as a result of an increase in SV. These results were explainable on the basis of the different HR behavior between the two settings, which in turn led to different diastolic time and myocardial performance.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/91350
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 34
  • Scopus 63
  • ???jsp.display-item.citation.isi??? 59
social impact