Purpose: Carotid artery stenosis quantification is still considered a leading parameter in the choice of the therapeutic option. Our purpose was to asses the concordance between radiologist and a semi-automatic computer software in the stenosis quantification of carotid artery studied by using a Multi-Detector-Row CT angiography (MDCTA). Methods and material: 45 patients studied by using a 40-detector row CT scanner were retrospectively analyzed. Carotid artery stenosis was quantified by one high experienced radiologist in vessel analysis and by using a dedicated software. Carotid artery stenosis was calculated according to the ECST method. Bland-Altman statistics was used to measure the inter- and intra-concordance between radiologist and software and correlation coefficient between measures were performed by using nonparametric Spearmann correlation statistic. A p value < 0.05 was considered to mean statistical significance. Results: A strength correlation according to linear regression (correlation Spearman' ρ coefficient = 0.975; p < 0.0001) between radiologist and software of vessel analysis was observed. Between first and second stenosis of carotid artery quantification performed by radiologist and software of vessel analysis we observed a Spearman' ρ coefficient = 0.943 (p < 0.0001) and a Spearman' ρ coefficient = 0.9879; (p < 0.0001) respectively. Conclusions: Our results indicated that there is a strength correlation according to linear regression between stenosis of carotid artery quantification performed by radiologist and semi-automatic software. Reproducibility between measurements performed by semi-automatic software are higher compared to radiologist

Carotid artery stenosis quantification: concordance analysis between radiologist and semi-automatic computer software by using Multi-Detector-Row CT angiography

SABA, LUCA;SANFILIPPO, ROBERTO;MONTISCI, ROBERTO;
2011-01-01

Abstract

Purpose: Carotid artery stenosis quantification is still considered a leading parameter in the choice of the therapeutic option. Our purpose was to asses the concordance between radiologist and a semi-automatic computer software in the stenosis quantification of carotid artery studied by using a Multi-Detector-Row CT angiography (MDCTA). Methods and material: 45 patients studied by using a 40-detector row CT scanner were retrospectively analyzed. Carotid artery stenosis was quantified by one high experienced radiologist in vessel analysis and by using a dedicated software. Carotid artery stenosis was calculated according to the ECST method. Bland-Altman statistics was used to measure the inter- and intra-concordance between radiologist and software and correlation coefficient between measures were performed by using nonparametric Spearmann correlation statistic. A p value < 0.05 was considered to mean statistical significance. Results: A strength correlation according to linear regression (correlation Spearman' ρ coefficient = 0.975; p < 0.0001) between radiologist and software of vessel analysis was observed. Between first and second stenosis of carotid artery quantification performed by radiologist and software of vessel analysis we observed a Spearman' ρ coefficient = 0.943 (p < 0.0001) and a Spearman' ρ coefficient = 0.9879; (p < 0.0001) respectively. Conclusions: Our results indicated that there is a strength correlation according to linear regression between stenosis of carotid artery quantification performed by radiologist and semi-automatic software. Reproducibility between measurements performed by semi-automatic software are higher compared to radiologist
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/98348
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 9
social impact