The failure modes of K-joints of Concrete Filled Steel Tubular (CFST) truss structures were investigated through laboratory tests. CFST K-joint specimens consisted of a tubular chord filled with concrete and two braces inclined at the same angle with respect to the chord. Their size was chosen of the same scale as that of joints of real tubular structures currently used in bridges. The results were compared with those obtained by testing K-joint specimens of Circular Hollow Section (CHS) truss structures with the same size. Contrary to CHS K-joints, where a chord face failure mode occurred, in CFST K-joints no failure mode with inward deformation of the chord section can occur. Hence, punching shear failure was shown to be the typical failure mode of CFST K-joints, if no brace failure mode occurred before. Resistance of CFST K-joints to punching shear was then compared with the resistance values calculated through the Eurocode 3 and the AWS code formulae on CHS K-joints. The values provided by the former formula were quite close to (although always lower than) the actual resistance to punching shear of CFST K-joints. Finally, the favourable effect on joint resistance due to additional studs welded to the interior surface of the chord tube of CFST K-joint was also investigated.

Experimental study on K-joints of concrete-filled steel tubular truss structures

FENU, LUIGI;
2015-01-01

Abstract

The failure modes of K-joints of Concrete Filled Steel Tubular (CFST) truss structures were investigated through laboratory tests. CFST K-joint specimens consisted of a tubular chord filled with concrete and two braces inclined at the same angle with respect to the chord. Their size was chosen of the same scale as that of joints of real tubular structures currently used in bridges. The results were compared with those obtained by testing K-joint specimens of Circular Hollow Section (CHS) truss structures with the same size. Contrary to CHS K-joints, where a chord face failure mode occurred, in CFST K-joints no failure mode with inward deformation of the chord section can occur. Hence, punching shear failure was shown to be the typical failure mode of CFST K-joints, if no brace failure mode occurred before. Resistance of CFST K-joints to punching shear was then compared with the resistance values calculated through the Eurocode 3 and the AWS code formulae on CHS K-joints. The values provided by the former formula were quite close to (although always lower than) the actual resistance to punching shear of CFST K-joints. Finally, the favourable effect on joint resistance due to additional studs welded to the interior surface of the chord tube of CFST K-joint was also investigated.
2015
CFST; Failure mode; Joint; Resistance; Truss; Tubular structures; Building and Construction; Civil and Structural Engineering; Mechanics of Materials; 2506
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0143974X15000255-main.pdf

Solo gestori archivio

Tipologia: versione editoriale (VoR)
Dimensione 2.59 MB
Formato Adobe PDF
2.59 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
JCSR testo con figure.pdf

Open Access dal 02/05/2017

Tipologia: versione post-print (AAM)
Dimensione 15.28 MB
Formato Adobe PDF
15.28 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/191196
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 60
  • ???jsp.display-item.citation.isi??? 48
social impact