The effective management of future smart grids is strictly related to the accurate knowledge of the network operating conditions via distribution system state estimation (DSSE). To achieve this target, the measurement infrastructure of the distribution systems needs a substantial upgrade. However, obvious economic limitations prevent a massive deployment of measurement instruments on the field in short times. As a consequence, ad hoc meter placement techniques have to be applied to define location and type of a minimum set of measurements required to obtain the desired accuracy performance. This paper presents a mathematical analysis showing the impact of current and power measurements on the accuracy of DSSE results. The goal is to provide the analytical tools to identify the best placement for additional current or power measurements when applying an incremental deployment of meters in the distribution system. The analysis has a general validity but has also a clear impact on practical situations when the monitoring systems are upgraded starting from an existing infrastructure. Tests on a 95-bus sample grid are presented in order to validate the found mathematical results and to highlight the associated benefits in a meter placement perspective.

Impact of Current and Power Measurements on Distribution System State Estimation Uncertainty

Pegoraro, Paolo Attilio;Muscas, Carlo;Sulis, Sara
2019-01-01

Abstract

The effective management of future smart grids is strictly related to the accurate knowledge of the network operating conditions via distribution system state estimation (DSSE). To achieve this target, the measurement infrastructure of the distribution systems needs a substantial upgrade. However, obvious economic limitations prevent a massive deployment of measurement instruments on the field in short times. As a consequence, ad hoc meter placement techniques have to be applied to define location and type of a minimum set of measurements required to obtain the desired accuracy performance. This paper presents a mathematical analysis showing the impact of current and power measurements on the accuracy of DSSE results. The goal is to provide the analytical tools to identify the best placement for additional current or power measurements when applying an incremental deployment of meters in the distribution system. The analysis has a general validity but has also a clear impact on practical situations when the monitoring systems are upgraded starting from an existing infrastructure. Tests on a 95-bus sample grid are presented in order to validate the found mathematical results and to highlight the associated benefits in a meter placement perspective.
2019
Current estimation; current measurements; distribution system state estimation (DSSE); meter placement; uncertainty analysis; weighted least squares (WLS) method.; Instrumentation; Electrical and Electronic Engineering
File in questo prodotto:
File Dimensione Formato  
TIM_IM-18-18520R_accepted_to_share.pdf

accesso aperto

Tipologia: versione post-print
Dimensione 797.81 kB
Formato Adobe PDF
797.81 kB Adobe PDF Visualizza/Apri
08574940_TIM_editorial.pdf

Solo gestori archivio

Descrizione: versione editoriale
Tipologia: versione editoriale
Dimensione 1.71 MB
Formato Adobe PDF
1.71 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/261736
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 23
  • ???jsp.display-item.citation.isi??? 20
social impact