The paper is focused on the emission of sub-micron particles from incinerator plants characterized by different treatment sections. In particular, measurement of particle number concentrations and distributions in different sampling points of the flue-gas treatment sections, and/or over several years, allowed to detect, for the very first time through in-field tests, the effect of the age of the fabric filter bags and of the SCR system on the emission of sub-micron particles. In fact, tests showed that the age of the fabric filter bags can affect the particle number concentrations at the stack: indeed, for older bags higher concentrations at the stack were measured likely due to the filter cleaning process. Concerning the effect of the SCR system, the natural gas combustion performed in the SCR system leads to an increase of sub-micron particle concentrations at the stack with respect to the values measured after the filtration section.

Effects of the flue gas treatment of incinerator plants on sub-micron particle concentrations at the stack

Frattolillo A.
Writing – Review & Editing
;
2020-01-01

Abstract

The paper is focused on the emission of sub-micron particles from incinerator plants characterized by different treatment sections. In particular, measurement of particle number concentrations and distributions in different sampling points of the flue-gas treatment sections, and/or over several years, allowed to detect, for the very first time through in-field tests, the effect of the age of the fabric filter bags and of the SCR system on the emission of sub-micron particles. In fact, tests showed that the age of the fabric filter bags can affect the particle number concentrations at the stack: indeed, for older bags higher concentrations at the stack were measured likely due to the filter cleaning process. Concerning the effect of the SCR system, the natural gas combustion performed in the SCR system leads to an increase of sub-micron particle concentrations at the stack with respect to the values measured after the filtration section.
2020
Ultrafine particles; Sub-micron particles; Incinerator plants; Fabric filter; Selective catalytic reduction (SCR); Filter efficiency; Condensation Particle Counter
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/309039
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 4
  • ???jsp.display-item.citation.isi??? 2
social impact