Background: The alveolar antral artery (AAA) is a vascular structure that often passes through the area of lateral window opening during sinus augmentation and can reach dimensions that, if the vessel is severed, can represent a serious complication of the surgical procedure. Purpose: With this narrative review, we aimed at summarizing the results obtained from all the studies that analyzed the variability in anatomical position and dimension of the AAA in order to give the clinician a reference when planning for a sinus augmentation surgery. Materials and Methods: A search of available literature was conducted using electronic databases (PubMed and Medline) and manual searching. Results: Detection rate of AAA on cone beam computerized tomography (CBCT) is variable and may depend upon the experience of the clinician. The course of the vessel is most frequently intraosseous, and its diameter, despite being smaller than 1 mm in most of the cases, can have a high incidence of diameters between 1 mm and 2 mm. Mean distances of the AAA from alveolar crest and sinus floor range from 11.25 mm to 26.90 mm and 5.80 mm to 10.40 mm. Conclusions: Anatomical variants of the AAA that may increase the risk of severe intraoperatory bleeding are frequent and must be detected by the clinician implementing the use of the CBCT.

Anatomical Considerations on the Alveolar Antral Artery as Related to the Sinus Augmentation Surgical Procedure

Valente N. A.
Primo
2016-01-01

Abstract

Background: The alveolar antral artery (AAA) is a vascular structure that often passes through the area of lateral window opening during sinus augmentation and can reach dimensions that, if the vessel is severed, can represent a serious complication of the surgical procedure. Purpose: With this narrative review, we aimed at summarizing the results obtained from all the studies that analyzed the variability in anatomical position and dimension of the AAA in order to give the clinician a reference when planning for a sinus augmentation surgery. Materials and Methods: A search of available literature was conducted using electronic databases (PubMed and Medline) and manual searching. Results: Detection rate of AAA on cone beam computerized tomography (CBCT) is variable and may depend upon the experience of the clinician. The course of the vessel is most frequently intraosseous, and its diameter, despite being smaller than 1 mm in most of the cases, can have a high incidence of diameters between 1 mm and 2 mm. Mean distances of the AAA from alveolar crest and sinus floor range from 11.25 mm to 26.90 mm and 5.80 mm to 10.40 mm. Conclusions: Anatomical variants of the AAA that may increase the risk of severe intraoperatory bleeding are frequent and must be detected by the clinician implementing the use of the CBCT.
2016
Computerized tomography; Cone beam CT; Maxillary sinus; Maxillary sinus floor elevation; Sinus augmentation; Sinus floor elevation
File in questo prodotto:
File Dimensione Formato  
10.1111_cid.12355 copia.pdf

Solo gestori archivio

Tipologia: versione editoriale (VoR)
Dimensione 244.12 kB
Formato Adobe PDF
244.12 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/320861
Citazioni
  • ???jsp.display-item.citation.pmc??? 7
  • Scopus 24
  • ???jsp.display-item.citation.isi??? 23
social impact