Hydrosalpinx is a condition with a crucial prognostic role in reproduction, and its diagnosis by a non-invasive technique such as ultrasound is key in achieving an adequate reproductive assessment while avoiding unnecessary laparoscopies. The aim of the present systematic review and meta-analysis is to synthetize and report the current evidence on transvaginal sonography (TVS) accuracy to diagnose hydrosalpinx. Articles on the topic published between January 1990 and December 2022 were searched in five electronic databases. Data from the six selected studies, comprising 4144 adnexal masses in 3974 women, 118 of which were hydrosalpinxes, were analyzed as follows: overall, TVS had a pooled estimated sensitivity for hydrosalpinx of 84% (95% confidence interval (CI) = 76-89%), specificity of 99% (95% CI = 98-100%), positive likelihood ratio of 80.7 (95% CI = 33.7-193.0), and negative likelihood ratio of 0.16 (95% CI = 0.11-0.25) and DOR of 496 (95% CI = 178-1381). The mean prevalence of hydrosalpinx was 4%. The quality of the studies and their risk of bias were assessed using QUADAS-2, evidencing an overall acceptable quality of the selected articles. We concluded that TVS has a good specificity and sensitivity for diagnosing hydrosalpinx.

Transvaginal Ultrasound Accuracy in the Hydrosalpinx Diagnosis: A Systematic Review and Meta-Analysis

Guerriero, Stefano;
2023-01-01

Abstract

Hydrosalpinx is a condition with a crucial prognostic role in reproduction, and its diagnosis by a non-invasive technique such as ultrasound is key in achieving an adequate reproductive assessment while avoiding unnecessary laparoscopies. The aim of the present systematic review and meta-analysis is to synthetize and report the current evidence on transvaginal sonography (TVS) accuracy to diagnose hydrosalpinx. Articles on the topic published between January 1990 and December 2022 were searched in five electronic databases. Data from the six selected studies, comprising 4144 adnexal masses in 3974 women, 118 of which were hydrosalpinxes, were analyzed as follows: overall, TVS had a pooled estimated sensitivity for hydrosalpinx of 84% (95% confidence interval (CI) = 76-89%), specificity of 99% (95% CI = 98-100%), positive likelihood ratio of 80.7 (95% CI = 33.7-193.0), and negative likelihood ratio of 0.16 (95% CI = 0.11-0.25) and DOR of 496 (95% CI = 178-1381). The mean prevalence of hydrosalpinx was 4%. The quality of the studies and their risk of bias were assessed using QUADAS-2, evidencing an overall acceptable quality of the selected articles. We concluded that TVS has a good specificity and sensitivity for diagnosing hydrosalpinx.
2023
Diagnosis; Hydrosalpinx; Transvaginal ultrasound
File in questo prodotto:
File Dimensione Formato  
diagnostics-13-00948.pdf

accesso aperto

Tipologia: versione editoriale
Dimensione 2.09 MB
Formato Adobe PDF
2.09 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/394709
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact