Photoplethysmography is gaining increasing attention for the measurement of heart rate (HR) and heart rate variability (HRV), but the accuracy and reliability of measurement results remain questionable when obtained from wearable devices, prone to recording movement artifacts and other disturbances caused by poor sensor-skin contact. HR and HRV information is typically extracted in the time domain, from the estimation of inter-beat intervals, which can be confidently identified only when the signal is very clean. This paper proposes an alternative time-frequency approach to the HR estimation, based on the Taylor-Fourier analysis, which allows obtaining the instantaneous HR, as opposed to the traditional beat-to-beat average HR, with associated benefits in terms of time resolution (especially for HRV measurements), no quantization, and enhanced robustness in presence of moderate signal distortion. Experimental tests on a healthy subject wearing the Empatica E4 wristband have been complemented by additional validation on a dataset of recordings from 18 healthy subjects, using the same device; in all cases, the results from the proposed method have been compared to HR measurements from electrocardiography, with very good agreement. The results have also been compared to the closest alternatives for instantaneous HR estimation, relying on the Short-Time Fourier Transform, or on the Empirical Mode Decomposition combined with the Hilbert Transform, confirming the noticeable benefits provided by the proposed model-based approach, particularly evident in its ability to better reveal the high-frequency HR oscillations, mainly caused by respiration.

Application of Taylor-Fourier Analysis to Photoplethysmography Signals for Instantaneous Heart Rate Measurement

Pegoraro, Paolo Attilio;
2025-01-01

Abstract

Photoplethysmography is gaining increasing attention for the measurement of heart rate (HR) and heart rate variability (HRV), but the accuracy and reliability of measurement results remain questionable when obtained from wearable devices, prone to recording movement artifacts and other disturbances caused by poor sensor-skin contact. HR and HRV information is typically extracted in the time domain, from the estimation of inter-beat intervals, which can be confidently identified only when the signal is very clean. This paper proposes an alternative time-frequency approach to the HR estimation, based on the Taylor-Fourier analysis, which allows obtaining the instantaneous HR, as opposed to the traditional beat-to-beat average HR, with associated benefits in terms of time resolution (especially for HRV measurements), no quantization, and enhanced robustness in presence of moderate signal distortion. Experimental tests on a healthy subject wearing the Empatica E4 wristband have been complemented by additional validation on a dataset of recordings from 18 healthy subjects, using the same device; in all cases, the results from the proposed method have been compared to HR measurements from electrocardiography, with very good agreement. The results have also been compared to the closest alternatives for instantaneous HR estimation, relying on the Short-Time Fourier Transform, or on the Empirical Mode Decomposition combined with the Hilbert Transform, confirming the noticeable benefits provided by the proposed model-based approach, particularly evident in its ability to better reveal the high-frequency HR oscillations, mainly caused by respiration.
2025
Heart rate; Heart rate variability; Estimation; Signal processing; Time-frequency analysis; Signal resolution; Distortion measurement; Accuracy; Electrocardiography; Distortion
File in questo prodotto:
File Dimensione Formato  
10.1109TIM.2025.3621748_postprint_coveririsunica.pdf

accesso aperto

Tipologia: versione post-print (AAM)
Dimensione 1.6 MB
Formato Adobe PDF
1.6 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/456566
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact