A practical method is proposed for complete gain measurement in distributed feedback (DFB) laser diodes. It is non-destructive and does not require any reference device. It includes the whole range of continuous gain values, from its minimum to threshold, passing through the transparency condition. The method requires a single absolute gain measurement for calibration. An example is reported for a DFB preserving Fabry-Perot multi-modes in the sub-threshold regime.
Extended Modal Gain Measurement in DFB Laser Diodes
VANZI, MASSIMO;MARCELLO, GIULIA;MURA, GIOVANNA;
2017-01-01
Abstract
A practical method is proposed for complete gain measurement in distributed feedback (DFB) laser diodes. It is non-destructive and does not require any reference device. It includes the whole range of continuous gain values, from its minimum to threshold, passing through the transparency condition. The method requires a single absolute gain measurement for calibration. An example is reported for a DFB preserving Fabry-Perot multi-modes in the sub-threshold regime.File in questo prodotto:
File | Dimensione | Formato | |
---|---|---|---|
07762038(1).pdf
Solo gestori archivio
Tipologia:
versione editoriale (VoR)
Dimensione
424.01 kB
Formato
Adobe PDF
|
424.01 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.