In this paper, ordinary FMEA (Failure Mode and Effects Analysis) was applied during the design phase of an electric motor control system for vehicle HVAC (Heating/Ventilation/Air Conditioning). The analysis of the field data from the second year forces to review FMEA. The corrective actions, planned on the basis of the sole failure mode, as usual in FMEA, proved to be inadequate and Failure Analysis was performed to understand the failure mechanism of the indicted component and integrate. New proper corrective actions were devised and successfully implemented.

Failure Analysis-assisted FMEA

MURA, GIOVANNA;VANZI, MASSIMO;
2006-01-01

Abstract

In this paper, ordinary FMEA (Failure Mode and Effects Analysis) was applied during the design phase of an electric motor control system for vehicle HVAC (Heating/Ventilation/Air Conditioning). The analysis of the field data from the second year forces to review FMEA. The corrective actions, planned on the basis of the sole failure mode, as usual in FMEA, proved to be inadequate and Failure Analysis was performed to understand the failure mechanism of the indicted component and integrate. New proper corrective actions were devised and successfully implemented.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11584/98547
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 58
  • ???jsp.display-item.citation.isi??? 42
social impact